BackgroundIn recent years, a variety of short stems have been introduced. To date, mid- and long-term results of calcar-guided short-stem designs have been rarely available.Materials and methodsTwo hundred and sixteen calcar-guided short stems were included in combination with a cementless cup in a prospective study. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) as well as pain and satisfaction on visual analogue scale (VAS) were assessed during a median follow-up of 61.7 months. Standardised radiographs were analysed at predefined time points regarding radiological alterations such as bone resorption and remodelling, radiolucency, osteolysis and cortical hypertrophy using modified Gruen zones.ResultsAt mid-term follow-up, no revision surgery of the stem had to be performed in the whole collective. At 5 years, HHS was 97.8 (SD 4.7), satisfaction on VAS was 9.7 (SD 0.7), rest pain on VAS was 0.1 (SD 0.5), and load pain on VAS was 0.6 (SD 1.2). Compared to the 2-year results, femoral bone resorption increased significantly at the 5-year follow-up (3.9% versus 42.3%). Rate of femoral cortical hypertrophy remained stable, occurring in a total of 9 hips (4.5%). At the 5-year follow-up, 2 stems (1.0%) showed non-progressive radiolucent lines with a maximum width of 2 mm. Signs of osteolysis were not observed. Compared to the 2-year follow-up, no further subsidence was observed.ConclusionsThe rate of stem revision (0%) at the mid-term follow-up was remarkable and indicates the principle of using a calcar-guided short stem as being a safe procedure. However, signs of bone-remodelling, indicating some amount of stress-shielding, must be acknowledged at 5 years depending on stem alignment and type of anchorage.Level of evidenceIV, Prospective observational studyTrial registration German Clinical Trials Register, DRKS00012634, 07/07/2017 (retrospectively registered)
IntroductionShort-stem THA has become increasingly popular over the last decade. However, implantation technique differs from conventional THA and thus possibly involves a distinct learning curve. The purpose of this study was to evaluate the value of intraoperative radiography and the influence of the surgeon’s experience on intraoperative adjustments in short-stem THA.MethodsA total of 287 consecutive short-stem THAs, operated by a total of 24 senior consultants, consultants and residents in training, were prospectively included. Intraoperative radiography was performed after trial reduction. Preoperative planning and intraoperative outcome with regard to positioning, sizing of components as well as resulting offset and leg length were compared. Frequency, reason and type of intraoperative adjustments were documented in relation to the surgeon’s experience. Operation time was assessed.ResultsOne hundred and fifty-six (54.4%) procedures were carried out by one of three senior consultants, and a total of nine consultants and 12 residents in training performed 105 (36.6%) and 26 (9.0%) operations, respectively. In 121 cases (42.2%), intraoperative adjustments were made following intraoperative radiography. Intraoperative adjustments of one or more components were made by senior consultants in 51 cases (32.7%), by consultants in 53 cases (50.5%) and by residents in 17 cases (65.4%), respectively. The most common cause was undersizing of the stem. Operation time varied markedly between groups of surgeons.DiscussionShort-stem THA involves a learning curve. Intraoperative radiography is decisive for prevention of malpositioning and undersizing of components, as well as loss of offset and leg length discrepancies. Hence, it should be considered mandatory, especially for less experienced surgeons.
Distal chevron osteotomy is a common procedure for surgical correction of hallux valgus. Osteosynthesis with 1 screw or 2 Kirschner wires has been commonly used. We compared the stability of the 2 techniques in distal chevron osteotomy. Sixteen first metatarsals from fresh-frozen human cadaver feet (9 different cadaveric specimens) were used. A standardized distal chevron osteotomy was performed. One first metatarsal from each pair was assigned to group 1 (3.5-mm cortical screw; n = 8) and one to group 2 (two 1.6-mm Kirschner wires; n = 8). Using a materials testing machine, the head of the first metatarsals was loaded in 2 different configurations (cantilever and physiologic) in succession. In the cantilever configuration, the relative stiffness of the osteosynthesis compared with intact bone was 59% ± 27% in group 1 and 68% ± 18% in group 2 (p = .50). In the physiologic configuration, it was 38% ± 25% in group 1 and 35% ± 7% in group 2 (p = .75). The failure strength in the cantilever configuration was 187 ± 105 N in group 1 and 259 ± 71 N in group 2 (p = .21). No statistically significant differences were found in stability between the 2 techniques. The use of 1 screw or 2 Kirschner wires had no significant differences in their biomechanical loading capacity for osteosynthesis in distal chevron osteotomies for treatment of hallux valgus.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.