Enrichment methods used in sample preparation for the bioanalytical assessment of disinfected drinking water result in the loss of volatile and hydrophilic disinfection byproducts (DBPs) and hence likely tend to underestimate biological effects. We developed and evaluated methods that are compatible with bioassays, for extracting nonvolatile and volatile DBPs from chlorinated and chloraminated drinking water to minimize the loss of analytes. For nonvolatile DBPs, solid-phase extraction (SPE) with TELOS ENV as solid phase performed superior compared to ten other sorbents. SPE yielded >70% recovery of nonpurgeable adsorbable organic halogens (AOX). For volatile DBPs, cryogenic vacuum distillation performed unsatisfactorily. Purge and cold-trap with crushed ice serving as condensation nuclei achieved recoveries of 50-100% for trihalomethanes and haloacetonitriles and approximately 60-90% for purged AOX from tap water. We compared the purgeable versus the nonpurgeable fraction by combining purge-and-trap extraction with SPE. The purgeable DBP fraction enriched with the purge-and-trap method exerted a lower oxidative stress response in mammalian cells than the nonpurgeable DBPs enriched with SPE after purging, while contributions of both fractions to bacterial cytotoxicity was more variable. 37 quantified DBPs explained almost the entire AOX in the purge-and-trap extracts, but <16% in the SPE extracts demonstrating that the nonpurgeable fraction is dominated by unknown DBPs.
Isotopic measurements of leaf water have provided insights into a range of ecophysiological and biogeochemical processes, but require an extraction step which often constitutes the major analytical bottleneck in large-scale studies. Current standard procedures for leaf water analysis are based on cryogenic vacuum or azeotrophic distillation, and are laborious, require sophisticated distillation lines and the use of toxic materials. We report a rapid technique based on centrifugation/filtration of leaf samples pulverised in their original sampling tubes, using a specifically adapted, simple apparatus. The leaf water extracts produced are suitable for isotopic analysis via pyrolysis gas chromatography isotope ratio mass spectrometry (PYR/GC/IRMS). The new method was validated against cryogenic vacuum distillation and showed an overall accuracy of +/-0.5 per thousand (nine grouped comparisons, n = 110) over a range of 21 per thousand. Effects due to the presence of soluble carbohydrates were near the detection limits for most samples analysed, and these effects could be corrected for (the extracted soluble organics could also be used for isotopic analysis). The extraction time for a routine eight-sample subset was reduced from 4 h (cryogenic distillation) to 45 min, limited only by the size of the centrifuge(s) used. This method provides a rapid, low-cost and reliable alternative to conventional vacuum and other distillation methods that can alleviate current restrictions on ecosystem- and global-scale studies that require high-throughput leaf water isotopic analysis.
Analysis of the stable isotopic composition of atmospheric moisture is widely applied in the environmental sciences. Traditional methods for obtaining isotopic compositional data from ambient moisture have required complicated sampling procedures, expensive and sophisticated distillation lines, hazardous consumables, and lengthy treatments prior to analysis. Newer laser-based techniques are expensive and usually not suitable for large-scale field campaigns, especially in cases where access to mains power is not feasible or high spatial coverage is required. Here we outline the construction and usage of a novel vapour-sampling system based on a battery-operated Stirling cycle cooler, which is simple to operate, does not require any consumables, or post-collection distillation, and is light-weight and highly portable. We demonstrate the ability of this system to reproduce delta(18)O isotopic compositions of ambient water vapour, with samples taken simultaneously by a traditional cryogenic collection technique. Samples were collected over 1 h directly into autosampler vials and were analysed by mass spectrometry after pyrolysis of 1 microL aliquots to CO. This yielded an average error of < +/-0.5 per thousand, approximately equal to the signal-to-noise ratio of traditional approaches. This new system provides a rapid and reliable alternative to conventional cryogenic techniques, particularly in cases requiring high sample throughput or where access to distillation lines, slurry maintenance or mains power is not feasible.
This paper reports concentrations between ~1950 and present, of polybrominated diphenyl ethers (PBDEs) and polybrominated dibenzo-p-dioxins and furans (PBDD/Fs), in radiometrically-dated sediment cores from three English lakes. Mixed bromo/chloro dibenzo-p-dioxins and furans (PXDD/Fs) were measured in two of the same lakes. Concentrations of PXDD/Fs decreased over time to the present. To our knowledge, this is the first report of temporal trends of PXDD/Fs in the environment. In contrast, concentrations of PBDEs increased towards the present and were significantly correlated (R= 0.88-0.98; p<0.05) with concentrations of PBDFs in all three lakes. These observations suggest that the sources of PXDD/Fs are not related to PBDEs and differ from those of PBDFs. We also report for the first time the presence of octabromodibenzofuran (OBDF) in the two most recent core slices at one lake. The source of OBDF in these samples is unclear. While OBDF has been reported previously as a significant contaminant of some commercial formulations of Deca-BDE, it is also present in Octa-BDE products and in emissions from a variety of combustion activities. Overall, while the positive correlation between PBDEs and PBDFs suggests increased use of PBDEs has contributed substantially to environmental contamination with PBDFs; examination of PBDF homologue patterns implies emissions from combustion activities are likely also important.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.