Two adult patients were diagnosed with extralobar and intralobar pulmonary sequestration. One patient presented with haemoptysis. Both patients suffered from recurrent episodes of severe pulmonary infections. Both patients were treated by means of endovascular embolization using Amplatzer(®) vascular plugs (AVPs). They were discharged from hospital after 48 and 24 h and then followed up for 24 and six months, respectively. No recurrence of symptoms was observed. Computed tomography scans were obtained every six months. Persistent occlusion of vascular supply and moderate regression of the sequestered lung tissue are evident after 24 and six months in both patients. Just one case of an adult patient affected by pulmonary sequestration and treated by endovascular embolization has been reported to date. The present report is the first on the use of the AVPs in adults for this condition. The potential advantages and drawbacks of this treatment modality in adults are discussed, as well the specific benefit represented by the AVPs.
Flexible fiberoptic bronchoscopy is an indispensable tool for optimal management of intensive care unit patients. However, the acquisition of sufficient training in bronchoscopy is not straightforward during residency, because of technical and ethical problems. Moreover, the use of commercial simulators is limited by their high cost. In order to overcome these limitations, we realized a low-cost anatomical simulator to acquire and maintain the basic skill to perform bronchoscopy in ventilated patients. We used 1.5 mm diameter iron wire to construct the bronchial tree scaffold; glazier-putty was applied to create the anatomical model. The model was covered by several layers of newspaper strips previously immersed in water and vinilic glue. When the model completely dried up, it was detached from the scaffold by cutting it into six pieces, it was reassembled, painted and fitted with an endotracheal tube. We used very cheap material and the final cost was euro16. The trainer resulted in real-scale and anatomically accurate, with appropriate correspondence on endoscopic view between model and patients. All bronchial segments can be explored and easily identified by endoscopic and external vision. This cheap simulator is a valuable tool for practicing, particularly in a hospital with limited resources for medical training.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.