Parkinson’s disease (PD) is a neurodegenerative disease characterized by the loss of dopaminergic neurons in the substantia nigra pars compacta, leading to alteration of the integrity of dopaminergic transporters (DATs). In recent years, some radiopharmaceuticals have been used in the clinic to evaluate the integrity of DATs. These include tropane derivatives such as radiolabeled β-CIT and FP-CIT with iodine-123 (123I), and TRODAT-1 with metastable technetium-99 (99mTc). Radiolabeling of β-CIT with radioactive iodine is based on electrophilic radioiodination using oxidizing agents, such as Chloramine T or Iodo-Gen®. For the first time, the present work performed a comparative study of the radiolabeling of β-CIT with iodine-131 (131I), using either Chloramine T or Iodo-Gen® as oxidizing agents, in order to improve the radiolabeling process of β-CIT and to choose the most advantageous oxidizing agent to be used in nuclear medicine. Both radiolabeling methods were similar and resulted in high radiochemical yield (> 95%), with suitable 131I-β-CIT stability up to 72 h. Although Chloramine T is a strong oxidizing agent, it was as effective as Iodo-Gen® for β-CIT radiolabeling with 131I, with the advantage of briefer reaction time and solubility in aqueous medium.
The purpose of the present study was to develop and assess a novel sustained-release drug delivery system of Bimatoprost (BIM). Chitosan polymeric inserts were prepared using the solvent casting method and characterized by swelling studies, infrared spectroscopy, differential scanning calorimetry, drug content, scanning electron microscopy and in vitro drug release. Biodistribution of 99mTc-BIM eye drops and 99mTc-BIM-loaded inserts, after ocular administration in Wistar rats, was accessed by ex vivo radiation counting. The inserts were evaluated for their therapeutic efficacy in glaucomatous Wistar rats. Glaucoma was induced by weekly intracameral injection of hyaluronic acid. BIM-loaded inserts (equivalent to 9.0 µg BIM) were administered once into conjunctival sac, after ocular hypertension confirmation. BIM eye drop was topically instilled in a second group of glaucomatous rats for 15 days days, while placebo inserts were administered once in a third group. An untreated glaucomatous group was used as control. Intraocular pressure (IOP) was monitored for four consecutive weeks after treatment began. At the end of the experiment, retinal ganglion cells and optic nerve head cupping were evaluated in the histological eye sections. Characterization results revealed that the drug physically interacted, but did not chemically react with the polymeric matrix. Inserts sustainedly released BIM in vitro during 8 hours. Biodistribution studies showed that the amount of 99mTc-BIM that remained in the eye was significantly lower after eye drop instillation than after chitosan insert implantation. BIM-loaded inserts lowered IOP for 4 weeks, after one application, while IOP values remained significantly high for the placebo and untreated groups. Eye drops were only effective during the daily treatment period. IOP results were reflected in RGC counting and optic nerve head cupping damage. BIM-loaded inserts provided sustained release of BIM and seem to be a promising system for glaucoma management.
Background: The positron emission tomography (PET) ligand 68 Ga-Glu-urea-Lys(Ahx)-HBED-CC (68 Ga-PSMA-11) targets the prostate-specific membrane antigen (PSMA), upregulated in prostate cancer cells. Although 68 Ga-PSMA-11 PET is widely used in research and clinical practice, full kinetic modeling has not yet been reported nor have simplified methods for quantification been validated. The aims of our study were to quantify 68 Ga-PSMA-11 uptake in primary prostate cancer patients using compartmental modeling with arterial blood sampling and to validate the use of standardized uptake values (SUV) and image-derived blood for quantification. Results: Fifteen patients with histologically proven primary prostate cancer underwent a 60-min dynamic 68 Ga-PSMA-11 PET scan of the pelvis with axial T1 Dixon, T2, and diffusion-weighted magnetic resonance (MR) images acquired simultaneously. Time-activity curves were derived from volumes of interest in lesions, normal prostate, and muscle, and mean SUV calculated. In total, 18 positive lesions were identified on both PET and MR. Arterial blood activity was measured by automatic arterial blood sampling and manual blood samples were collected for plasmato-blood ratio correction and for metabolite analysis. The analysis showed that 68 Ga-PSMA-11 was stable in vivo. Based on the Akaike information criterion, 68 Ga-PSMA-11 kinetics were best described by an irreversible two-tissue compartment model. The rate constants K 1 and k 3 and the net influx rate constants K i were all significantly higher in lesions compared to normal tissue (p < 0.05). K i derived using image-derived blood from an MR-guided method showed excellent agreement with K i derived using arterial blood sampling (intraclass correlation coefficient = 0.99). SUV correlated significantly with K i with the strongest correlation of scan time-window 30-45 min (rho 0.95, p < 0.001). Both K i and SUV correlated significantly with serum prostate specific antigen (PSA) level and PSA density. Conclusions: 68 Ga-PSMA-11 kinetics can be described by an irreversible two-tissue compartment model. An MR-guided method for image-derived blood provides a non-invasive alternative to blood sampling for kinetic modeling studies. SUV showed strong correlation with K i and can be used in routine clinical settings to quantify 68 Ga-PSMA-11 uptake.
Prostate-specific membrane antigen (PSMA) is a glycoprotein present in the prostate, that is overexpressed in prostate cancer (PCa). Recently, PSMA-directed radiopharmaceuticals have been developed, allowing the pinpointing of tumors with the Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) imaging techniques. The aim of the present work was to standardize and validate an automatic synthesis module-based radiolabeling protocol for [68Ga]Ga-PSMA-11, as well as to produce a radiopharmaceutical for PET imaging of PCa malignancies. [68Ga]Ga-PSMA-11 was evaluated to determine the radiochemical purity (RCP), stability in saline solution and serum, lipophilicity, affinity to serum proteins, binding and internalization to lymph node carcinoma of the prostate (LNCaP) cells, and ex vivo biodistribution in mice. The radiopharmaceutical was produced with an RCP of 99.06 ± 0.10%, which was assessed with reversed-phase high-performance liquid chromatography (RP-HPLC). The product was stable in saline solution for up to 4 h (RCP > 98%) and in serum for up to 1 h (RCP > 95%). The lipophilicity was determined as −3.80 ± 0.15, while the serum protein binding (SPB) was <17%. The percentages of binding to LNCaP cells were 4.07 ± 0.51% (30 min) and 4.56 ± 0.46% (60 min), while 19.22 ± 2.73% (30 min) and 16.85 ± 1.34% (60 min) of bound material was internalized. High accumulation of [68Ga]Ga-PSMA-11 was observed in the kidneys, spleen, and tumor, with a tumor-to-contralateral-muscle ratio of >8.5 and a tumor-to-blood ratio of >3.5. In conclusion, an automatic synthesis module-based radiolabeling protocol for [68Ga]Ga-PSMA-11 was standardized and the product was evaluated, thus verifying its characteristics for PET imaging of PCa tumors in a clinical environment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.