PurposeTo test the ability of machine learning classifiers (MLCs) using optical coherence tomography (OCT) and standard automated perimetry (SAP) parameters to discriminate between healthy and glaucomatous individuals, and to compare it to the diagnostic ability of the combined structure-function index (CSFI), general ophthalmologists and glaucoma specialists.DesignCross-sectional prospective study.MethodsFifty eight eyes of 58 patients with early to moderate glaucoma (median value of the mean deviation = −3.44 dB; interquartile range, -6.0 to -2.4 dB) and 66 eyes of 66 healthy individuals underwent OCT and SAP tests. The diagnostic accuracy (area under the ROC curve—AUC) of 10 MLCs was compared to those obtained with the CSFI, 3 general ophthalmologists and 3 glaucoma specialists exposed to the same OCT and SAP data.ResultsThe AUCs obtained with MLCs ranged from 0.805 (Classification Tree) to 0.931 (Radial Basis Function Network, RBF). The sensitivity at 90% specificity ranged from 51.6% (Classification Tree) to 82.8% (Bagging, Multilayer Perceptron and Support Vector Machine Gaussian). The CSFI had a sensitivity of 79.3% at 90% specificity, and the highest AUC (0.948). General ophthalmologists and glaucoma specialists’ grading had sensitivities of 66.2% and 83.8% at 90% specificity, and AUCs of 0.879 and 0.921, respectively. RBF (the best MLC), the CSFI, and glaucoma specialists showed significantly higher AUCs than that obtained by general ophthalmologists (P<0.05). However, there were no significant differences between the AUCs obtained by RBF, the CSFI, and glaucoma specialists (P>0.25).ConclusionOur findings suggest that both MLCs and the CSFI can be helpful in clinical practice and effectively improve glaucoma diagnosis in the primary eye care setting, when there is no glaucoma specialist available.
The current lack of consensus for diagnosing glaucoma makes it difficult to develop diagnostic tests derived from deep learning (DL) algorithms. In the present study, we propose an objective definition of glaucomatous optic neuropathy (GON) using clearly defined parameters from optical coherence tomography and standard automated perimetry. We then use the proposed objective definition as reference standard to develop a DL algorithm to detect GON on fundus photos. A DL algorithm was trained to detect GON on fundus photos, using the proposed objective definition as reference standard. The performance was evaluated on an independent test sample with sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and likelihood ratios (LR). The test sample had 2118 fundus photos from 585 eyes of 405 individuals. The AUC to discriminate between GON and normal was 0.92 with sensitivity of 77% at 95% specificity. LRs indicated that the DL algorithm provided large changes in the post-test probability of disease for the majority of eyes. A DL algorithm to evaluate fundus photos had high performance to discriminate GON from normal. The newly proposed objective definition of GON used as reference standard may increase the comparability of diagnostic studies of glaucoma across devices and populations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.