The clinical and radiological outcomes after endoscopic aqueductoplasty and interventriculostomy in children with an isolated fourth ventricle indicate that this procedure is feasible, effective, and safe.
Background: Teleradiology has the potential to link medical experts and specialties despite geographical separation. In a project report about hospital-based teleradiology, the significance of technical and human factors during the implementation and growth of a teleradiology network are explored. Evaluation: The article identifies major obstacles during the implementation and growth of the teleradiology network of the Berlin Trauma Hospital (BG Unfallkrankenhaus Berlin) between 2004 and 2020 in semi-structured interviews with senior staff members. Quantitative analysis of examination numbers, patient numbers, and profits relates the efforts of the staff members to the monetary benefits and success of the network. Identification of qualitative and quantitative factors for success: Soft and hard facilitators and solutions driving the development of the national teleradiology network are identified. Obstacles were often solved by technical innovations, but the time span between required personal efforts, endurance, and flexibility of local and external team members. The article describes innovations driven by teleradiology and hints at the impact of teleradiology on modern medical care by relating the expansion of the teleradiology network to patient transfers and profits. Conclusion: In addition to technical improvements, interpersonal collaborations were key to the success of the teleradiology network of the Berlin Trauma Hospital and remained a unique feature and selling point of this teleradiology network.
Background Cone beam CT (CBCT) is a widely available technique with possible indications in carpal ligament injuries. The accuracy of CBCT arthrography in diagnosing traumatic tears of the scapholunate ligament has not been reported. Questions/purposes (1) What is the diagnostic accuracy of CBCT and how does it relate to the accuracy of multislice CT arthrography and conventional arthrography in diagnosing scapholunate ligament tears? (2) What is the estimated magnitude of skin radiation doses of each method? Methods This secondary analysis of a previous prospective study included 71 men and women with suspected scapholunate ligament tears and indications for arthroscopy. Preoperative imaging was conventional arthrography and either MSCT arthrography for the first half of patients to be included (n = 36) or flat-panel CBCT arthrography for the remaining patients (n = 35). Index tests identified therapy-relevant SLL tears with dorsal or complete SLL ruptures, and these tears were compared with relevant SLL tears which were determined through arthroscopy as Geissler Stadium III and IV by probing the instable SL joint with a microhook or arthroscope. These injuries were treated by open ligament repair and Kirschner wire fixation. Accuracy values and 95% confidence intervals were calculated. Additional estimates of the radiation skin doses of each CBCT exam and two MSCT protocols were subsequently calculated using dose area products, dose length products, and CT dose indices. Results The diagnostic accuracy was high for all imaging methods. 95% CIs were broadly overlapping and therefore did not indicate differences between the diagnostic groups: Sensitivity of CBCT arthrography was 100% (95% CI 77 to 100), specificity was 95% (95% CI 76 to 99.9), positive predictive value was 93% (95% CI 68 to 99.8), and negative predictive value was 100% (95% CI 83 to 100). For MSCT arthrography, the sensitivity was 92% (95% CI 64 to 99.8), specificity was 96% (95% CI 78 to 99.9), positive predictive value was 92% (95% CI 64 to 99.8), and negative predictive value was 96% (95% CI 78 to 99.9). For conventional arthrography, the sensitivity was comparably high: 96% (95% CI 81 to 99.9). Specificity was (81% [95% CI 67 to 92]); the positive predictive value was 77% (95% CI 59 to 89) and negative predictive value was 97% (95% CI 86 to 99.9). Estimated mean (range) radiation skin doses were reported in a descriptive fashion and were 12.9 mSv (4.5 to 24.9) for conventional arthrography, and 3.2 mSv (2.0 to 4.8) for CBCT arthrography. Estimated radiation skin doses were 0.2 mSv and 12 mSv for MSCT arthrography, depending on the protocol. Conclusion Flat-panel CBCT arthrography can be recommended as an accurate technique to diagnose scapholunate ligament injuries after wrist trauma. Estimated skin doses are low for CBCT arthrography and adapted MSCT arthrography protocols. Level of Evidence Level III, diagnostic study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.