Laser welding is an innovative method that is frequently used and required by different disciplines and represents a technique of choice in a wide range of applications due to important advantages such as precision, speed, and flexibility. However, the welding method must be used properly otherwise it may deteriorate the mechanical properties of the welded metal and its environment. Therefore, the laser parameters should be precisely determined and carefully applied to the sample. The primary objective of this study was to investigate and propose optimal welding parameters that should be adjusted during the neodymium-doped yttrium aluminum garnet (Nd: YAG)-pulsed laser welding of austenitic stainless steel 316L in an air welding environment by using Argon shielding gas and in wet welding settings in serum medium. The investigation of the welding process in serum medium was conducted in order to propose the most suitable welding parameters being important for future possible medical applications of laser welding in in-vivo settings and thus to investigate the possibilities of the welding process inside the human body. In order to evaluate the quality of welding in air and of wet welding (in serum), a detailed parameter study has been conducted by variation of the laser energy, the welding speed and the focal position. The relationship between the depth of penetration and specific point energy (SPE) was also evaluated. The microstructure of the welded metal was examined by an optical microscope and scanning electron microscope (SEM). Based on the microscopy results, it was found that the largest depth of penetration (1380 µm) was achieved with 19 J laser energy in air medium, while the depth reached the largest value (1240 µm) in serum medium at 28 J laser energy. The increasing energy level showed opposite behavior for air and serum. The results of our study imply that when welding of 316L stainless steel is implemented properly in the body fluid, it would be a promising start for future in-vivo studies.
Creating dimples at the ideal geometries to enhance the tribological properties of the polyphenylene sulfide (PPS) composite surface is the principal purpose of this study. In this manner, the effects of focus position (FP), pulse number (PN), and energy used for the making dimple geometry were investigated. In the ablation process, Nd:YAG laser with 1064 nm wavelength was used. Optimum laser process parameters were intended to obtain the largest ratio of dimple depth to width, circular dimples with a minimum ratio of molten zone diameter to spot size. The most effective parameters for obtaining dimple of desired properties are pulse energy (PE) with 60.64%, pulse duration (PD) with 55.61%, and FP with 55.94% for aspect ratio, circularity, and ratio of the diameter of the dimple to the spot size, respectively. In order to achieve a high aspect ratio or good circularity or minimum molten zone-to-spot size ratio, Taguchi optimization predicted the laser parameters. In the confirmation experiment with the proposed parameters, the highest aspect ratio was obtained as 2.05, the best circularity was obtained as 1.05, and minimum molten zone-to-spot size ratio was obtained as 1.073. Using the Taguchi method, accurate results were found with less experimentation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.