Background The spatial position of internal fixation play a role in determining the stability of internal fixations, both in clinical practice and research. Researchers have examined the stability of FNS (Femoral neck system) in the presence of coronal plane changes. In our knowledge, due to the biomechanical limitations of the specimens, there are no mechanical studies on the sagittal variation of FNS. This study aimed to investigate the biomechanical behavior of sagittal variations on Pauwels type III femoral neck fractures treated with FNS through finite element analysis. Methods Finite element models including Pauwels type III femoral neck fracture and FNS were reconstructed. Five fracture models(superior, central, inferior, anterior, posterior) were created in accordance with the bolt location in the sagittal plane within the femoral head. Equivalent stress, shear stress, and total deformation of each model under the same physiological load were recorded. Results According to the results, the central model exhibited the slightest stress and displacement, with the exception of the superior model. The internal fixation stress of the superior model was smaller than that of the central model. However, the maximum interfragmentary stress, total deformation and shear resistance area of the superior model was larger than that of the central model. Conclusions Central position of FNS in the sagittal plane allowed axial compression while reducing shear stress of internal fixation and interfragmentary equivalent stress. Off-axis fixation of the femoral neck increased the strain area and total displacement of the bone, raising the risk of fixation failure. Therefore, the central placement of FNS may be a better surgical target in the treatment of femoral neck fractures.
BACKGROUND: The femoral neck system (FNS) has been considered as a novel strategy for femoral neck fracture. The diversity of internal fixation creates difficulties in choosing an effective option for Pauwels III type femoral neck fractures. Therefore, it is significant to investigate the biomechanical effects of FNS versus conventional approaches on bones. OBJECTIVE: To evaluate the biomechanical characteristics of FNS versus cannulated screws coupled with medial plate (CSS+MP) for the treatment of Pauwels III type femoral neck fractures. METHODS: Through three-dimensional computer software (Minics, Geomagic – Warp), the proximal femur model was rebuilt. Based on the present clinical characteristics, models of internal fixation were reconstructed in SolidWorks, including cannulated screws (CSS), medial plate (MP) and FNS. After parameter setting and meshing, boundary conditions and loads were set up for the final mechanical calculation in Ansys Software. Under identical experimental conditions, such as the same Pauwels angle and force loading, the peak values of displacement, shear stress and equivalent (von Mises) stress were recorded. RESULTS: This study showed that the displacement of the models was CSS, CSS+MP, and FNS in descending order of magnitude. The shear stress and equivalent stress of the models was CSS+MP, FNS, and CSS in descending order. The principal shear stress of CSS+MP was concentrated on the medial plate. The equivalent stress of FNS was more dispersed and distributed from the proximal main nail to the distal locking screw. CONCLUSION: CSS+MP and FNS exhibited better initial stability compared to CSS. However, the MP was subjected to more shear stress, which could increase the risk of internal fixation failure. Due to its unique design, FNS may be a good choice for the treatment of Pauwels III type femoral neck fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.