In the paper, the specification of a new neutronics benchmark for a large Sodium cooled Fast Reactor core and results of modelling by different participants are presented. The neutronics benchmark describes the core of the French sodium cooled reactor Superphénix at its startup configuration, which in particular was used for experimental measurement of reactivity characteristics. The benchmark consists of the detailed heterogeneous core specification for neutronic analysis and results of the reference solution. Different core geometries and thermal conditions from cold “as fabricated” up to full power were considered. The reference Monte Carlo solution of Serpent 2 includes data on multiplication factor, power distribution, axial and radial reaction rates distribution, reactivity coefficients and safety characteristics, control rods worth, kinetic data. The results of modelling with seven other solutions using deterministic and Monte Carlo methods are also presented and compared to the reference solution. The comparisons results demonstrate appropriate agreement of evaluated characteristics. The neutronics results will be used in the second phase of the benchmark for evaluation of transient behaviour of the core.
Power Ramp test (PRT) of a fuel element is generally conducted with a PRT irradiation rig within a research reactor, in order to study the fuel’s behavior and validate its safety under power transient. Neutronics characteristics of a new PRT irradiation rig within a typical HFETR (High Flux Engineering Test Reactor) core and its components’ heat generation rates are calculated with MCNP code in this paper. The range of the test fuel rod power is obtained with a coupled Neutronic-Thermal-Hydraulic calculation method which combines MCNP and CFX code. The results show that changing the density of 3He gas can vary the test fuel rod power effectively, and the 3He gas layer influences the neutron field intensely by reducing the thermal neutron current into the layer and decreasing the neutron flux in and near the irradiation rig. The test fuel rod power varies from 5.80kW to 15.3kW while decreasing the 3He gas pressure from 4.5MPa to 0.13MPa, along with 0.231$ reactivity addition. Power of the fuel pellet in the test rod increases monotonically along with the 3He gas pressure reducing, and its calculation results have good agreement with the curve fitting by a natural logarithm function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.