Cartilage is responsive to the loading imposed during cyclic routine activities. However, the local relation between cartilage in terms of thickness distribution and biochemical composition and the local contact pressure during walking has not been established. The objective of this study was to evaluate the relation between cartilage thickness, proteoglycan and collagen concentration in the knee joint and knee loading in terms of contact forces and pressure during walking. 3D gait analysis and MRI (3D-FSE, T1ρ relaxation time and T2 relaxation time sequence) of fifteen healthy subjects were acquired. Experimental gait data was processed using musculoskeletal modeling to calculate the contact forces, impulses and pressure distribution in the tibiofemoral joint. Correlates to local cartilage thickness and mean T1ρ and T2 relaxation times of the weight-bearing area of the femoral condyles were examined. Local thickness was significantly correlated with local pressure: medial thickness was correlated with medial condyle contact pressure and contact force, and lateral condyle thickness was correlated with lateral condyle contact pressure and contact force during stance. Furthermore, average T1ρ and T2 relaxation time correlated significantly with the peak contact forces and impulses. Increased T1ρ relaxation time correlated with increased shear loading, decreased T1ρ and T2 relaxation time correlated with increased compressive forces and pressures. Thicker cartilage was correlated with higher condylar loading during walking, suggesting that cartilage thickness is increased in those areas experiencing higher loading during a cyclic activity such as gait. Furthermore, the proteoglycan and collagen concentration and orientation derived from T1ρ and T2 relaxation measures were related to loading.
Displacement encoding combined with relaxometry by MRI can noninvasively monitor the cartilage biomechanical and biochemical properties associated with loading. The deformation fields reveal complex patterns reflecting the depth-dependent mechanical properties, but intra-tissue deformation under compressive loading does not correlate with structural and compositional changes. The compacting effect of cyclic compression on the cartilage tissue was revealed by the change in relaxation time immediately after loading.
This study demonstrates that the local biomechanical changes occurring after defect creation may induce tissue damage by increasing shear strains and depletion of cartilage constituents at the defect rim under compressive loading.
ObjectivesThe current study quantified the influence of cartilage defect location on the tibiofemoral load distribution during gait. Furthermore, changes in local mechanical stiffness representative for matrix damage or bone ingrowth were investigated. This may provide insights in the mechanical factors contributing to cartilage degeneration in the presence of an articular cartilage defect.MethodsThe load distribution following cartilage defects was calculated using a musculoskeletal model that included tibiofemoral and patellofemoral joints with 6 degrees-of-freedom. Circular cartilage defects of 100 mm2 were created at different locations in the tibiofemoral contact geometry. By assigning different mechanical properties to these defect locations, softening and hardening of the tissue were evaluated.ResultsResults indicate that cartilage defects located at the load-bearing area only affect the load distribution of the involved compartment. Cartilage defects in the central part of the tibia plateau and anterior-central part of the medial femoral condyle present the largest influence on load distribution. Softening at the defect location results in overloading, i.e., increased contact pressure and compressive strains, of the surrounding tissue. In contrast, inside the defect, the contact pressure decreases and the compressive strain increases. Hardening at the defect location presents the opposite results in load distribution compared to softening. Sensitivity analysis reveals that the surrounding contact pressure, contact force and compressive strain alter significantly when the elastic modulus is below 7 MPa or above 18 MPa.ConclusionAlterations in local mechanical behavior within the high load bearing area resulted in aberrant loading conditions, thereby potentially affecting the homeostatic balance not only at the defect but also at the tissue surrounding and opposing the defect. Especially, cartilage softening predisposes the tissue to loads that may contribute to accelerated risk of cartilage degeneration and the initiation or progression towards osteoarthritis of the whole compartment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.