Purpose To validate a computed tomographic (CT) glomerular filtration rate (GFR) measurement and compare it with renal dynamic imaging GFR obtained by using the "Gates" method, with dual plasma sampling technetium 99m (Tc) diethylenetriaminepenta-acetic acid (DTPA) clearance ("true GFR") as the reference standard. Materials and Methods This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Forty-two patients with unilateral renal disease were included. Single-kidney CT GFR was calculated as excretory phase whole-kidney CT number enhancement divided by the area under the time-attenuation curve for the aorta, multiplied by (1 - hematocrit level). The CT GFR was then obtained by summing the result of the two sides. The true GFR and the Gates GFR were measured by using a single injection of Tc-DTPA. The CT GFR and Gates GFR were respectively compared with the true GFR by using a paired t test and linear regression analysis. Results The difference between CT GFR (mean ± standard deviation, 96.02 mL/min ± 23.11) and true GFR (90.50 mL/min ± 21.46) was 5.51 mL/min ± 6.96 (P< .001), demonstrating 6.09% systemic overestimation. The difference between Gates GFR (93.93 mL/min ± 26.97) and true GFR was 3.42 mL/min ± 16.10 (P = .176). Linear regression findings confirmed the association between CT GFR (y-axis) and true GFR (x-axis) and between Gates GFR (y-axis) and true GFR (x-axis) (P < .001 for both). Both regression lines paralleled the diagonal (intercept = 0 and slope = 1) (P = .599 and P = .945, respectively). The 95% confidence interval of the former was above the diagonal, confirming the systemic overestimation. The standard deviations of residuals of both linear regressions were 7.02 mL/min and 16.30 mL/min, respectively, demonstrating smaller deviation of the CT GFR (P < .001). Conclusion The proposed CT GFR measurement was validated in this study and was proved to be more accurate than the Gates method despite slight (6.09%) systemic overestimation. RSNA, 2016 Online supplemental material is available for this article.
A 33-year-old woman in the 6th month postpartum and breast-feeding period suffered from acute thoracolumbar pain for 1 month. She presented with slightly decreased serum calcium level. Other laboratory assessments were unremarkable. Considering the worsening symptom and her strong demand to exclude potential malignancy, F-FDG PET/CT was performed. Multiple FDG-avid foci in the thoracic and lumbar vertebra were detected on FDG PET, corresponding to vertebral compression fractures on CT, and diffuse FDG uptake was seen within bilateral breast, and dual-X ray absorptiometry showed markedly decreased bone mineral density, all of which supported the diagnosis of pregnancy and lactation-associated osteoporosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.