The aim of the present study was to assess the reliability of shear elastic modulus measurements performed using supersonic shear imaging (SSI) in nine resting muscles (i.e. gastrocnemius medialis, tibialis anterior, vastus lateralis, rectus femoris, triceps brachii, biceps brachii, brachioradialis, adductor pollicis obliquus and abductor digiti minimi) of different architectures and typologies. Thirty healthy subjects were randomly assigned to the intra-session reliability (n = 20), inter-day reliability (n = 21) and the inter-observer reliability (n = 16) experiments. Muscle shear elastic modulus ranged from 2.99 (gastrocnemius medialis) to 4.50 kPa (adductor digiti minimi and tibialis anterior). On the whole, very good reliability was observed, with a coefficient of variation (CV) ranging from 4.6% to 8%, except for the inter-operator reliability of adductor pollicis obliquus (CV = 11.5%). The intraclass correlation coefficients were good (0.871 ± 0.045 for the intra-session reliability, 0.815 ± 0.065 for the inter-day reliability and 0.709 ± 0.141 for the inter-observer reliability). Both the reliability and the ease of use of SSI make it a potentially interesting technique that would be of benefit to fundamental, applied and clinical research projects that need an accurate assessment of muscle mechanical properties.
Our results show homogeneous changes in muscle shear elastic modulus within and between elbow flexors. The greater increase in shear elastic modulus observed at long muscle lengths suggests the putative involvement of both cross-bridges number and titin in the modifications of muscle shear elastic modulus after damaging exercise.
This study demonstrates that the strain applied to human muscle fibres during eccentric contractions strongly influences the magnitude of muscle damage in vivo. Achilles tendon compliance decreases the amount of strain, while architectural gear ratio may moderately contribute to attenuating muscle fascicle lengthening and hence muscle damage. Further studies are necessary to explore the impact of various types of task to fully understand the contribution of muscle-tendon interactions during active lengthening to muscle damage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.