BackgroundMUNDUS is an assistive framework for recovering direct interaction capability of severely motor impaired people based on arm reaching and hand functions. It aims at achieving personalization, modularity and maximization of the user’s direct involvement in assistive systems. To this, MUNDUS exploits any residual control of the end-user and can be adapted to the level of severity or to the progression of the disease allowing the user to voluntarily interact with the environment. MUNDUS target pathologies are high-level spinal cord injury (SCI) and neurodegenerative and genetic neuromuscular diseases, such as amyotrophic lateral sclerosis, Friedreich ataxia, and multiple sclerosis (MS). The system can be alternatively driven by residual voluntary muscular activation, head/eye motion, and brain signals. MUNDUS modularly combines an antigravity lightweight and non-cumbersome exoskeleton, closed-loop controlled Neuromuscular Electrical Stimulation for arm and hand motion, and potentially a motorized hand orthosis, for grasping interactive objects.MethodsThe definition of the requirements and of the interaction tasks were designed by a focus group with experts and a questionnaire with 36 potential end-users.Five end-users (3 SCI and 2 MS) tested the system in the configuration suitable to their specific level of impairment. They performed two exemplary tasks: reaching different points in the working volume and drinking. Three experts evaluated over a 3-level score (from 0, unsuccessful, to 2, completely functional) the execution of each assisted sub-action.ResultsThe functionality of all modules has been successfully demonstrated. User’s intention was detected with a 100% success. Averaging all subjects and tasks, the minimum evaluation score obtained was 1.13 ± 0.99 for the release of the handle during the drinking task, whilst all the other sub-actions achieved a mean value above 1.6. All users, but one, subjectively perceived the usefulness of the assistance and could easily control the system. Donning time ranged from 6 to 65 minutes, scaled on the configuration complexity.ConclusionsThe MUNDUS platform provides functional assistance to daily life activities; the modules integration depends on the user’s need, the functionality of the system have been demonstrated for all the possible configurations, and preliminary assessment of usability and acceptance is promising.
Despite many approaches proposed in the past, robotic climbing in a complex vertical environment is still a big challenge. We present here an alternative climbing technology that is based on thermoplastic adhesive (TPA) bonds. The approach has a great advantage because of its large payload capacity and viability to a wide range of flat surfaces and complex vertical terrains. The large payload capacity comes from a physical process of thermal bonding, while the wide applicability benefits from rheological properties of TPAs at higher temperatures and intermolecular forces between TPAs and adherends when being cooled down. A particular type of TPA has been used in combination with two robotic platforms, featuring different foot designs, including heating/cooling methods and construction of footpads. Various experiments have been conducted to quantitatively assess different aspects of the approach. Results show that an exceptionally high ratio of 500% between dynamic payloads and body mass can be achieved for stable and repeatable vertical climbing on flat surfaces at a low speed. Assessments on four types of typical complex vertical terrains with a measure, i.e., terrain shape index ranging from −0.114 to 0.167, return a universal success rate of 80%-100%.
The investigation and characterization of sensori-motor learning and execution represents a key objective for the design of optimal rehabilitation therapies following stroke. By supplying new tools to investigate sensorimotor learning and objectively assess recovery, robot assisted techniques have opened new lines of research in neurorehabilitation aiming to complement current clinical strategies. Human studies, however, are limited by the complex logistics, heterogeneous patient populations and large dropout rates. Rat models may provide a substitute to explore the mechanisms underlying these processes in humans with larger and more homogeneous populations. This paper describes the development and evaluation of a three-degrees-of-freedom robotic manipulandum to train and assess precision forelimb movement in rats before and after stroke. The mechanical design is presented based on the requirements of interaction with rat kinematics and kinetics. The characterization of the robot exhibits a compact, low friction device, with a sufficient bandwidth suitable for motor training studies with rodents. The manipulandum was integrated with an existing training environment for rodent experiments and a first study is currently underway.
Vertical climbing on a variety of flat surfaces with a single robot has been previously demonstrated using vacuum suction, electrostatic adhesion, and biologically inspired approaches, etc. These methods generally have a low attachment strength, and it is not clear whether they can provide satisfactory attachment on vertical terrains with richer 3D features. Recent development of a climbing technology based on hot melt adhesives (HMAs) has shown its advantage with a high attachment strength through thermal bonding and viability to any solid surfaces. However, its feasibility for vertical climbing has only been proven on flat surfaces and with external energy supplies. This paper provides quantitative measurements for vertical climbing performance on five types of surfaces and terrains with a self-contained robot exploiting HMAs. We show that robust vertical climbing on multiple terrains can be achieved with reliable high-strength attachment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.