Lower limb exoskeletons are widely used for rehabilitation training of patients suffering from neurological disorders. To improve the human–robot interaction performance, series elastic actuators (SEAs) with low output impedance have been developed. However, the adaptability and control performance are limited by the constant spring stiffness used in current SEAs. In this study, a novel load-adaptive variable stiffness actuator (LaVSA) is used to design an ankle exoskeleton. To overcome the problems of the LaVSA with a larger mechanical gap and more complex dynamic model, a sliding mode controller based on a disturbance observer is proposed. During the interaction process, due to the passive joints at the load side of the ankle exoskeleton, the dynamic parameters on the load side of the ankle exoskeleton will change continuously. To avoid this problem, the designed controller treats it and the model error as a disturbance and observes it with the disturbance observer (DOB) in real time. The first-order derivative of the disturbance set is treated as a bounded value. Subsequently, the parameter adaptive law is used to find the upper bound of the observation error and make corresponding compensation in the control law. On these bases, a sliding mode controller based on a disturbance observer is designed, and Lyapunov stability analysis is given. Finally, simulation and experimental verification are performed. The wearing experiment shows that the resistance torque suffered by humans under human–robot interaction is lower than 120 Nmm, which confirms that the controller can realize zero-impedance control of the designed ankle exoskeleton.
With the gradual popularity of wearable devices, the demand for high-performance flexible wearable sensors is also increasing. Flexible sensors based on the optical principle have advantages e.g. anti-electromagnetic interference, antiperspirant, inherent electrical safety, and the potential for biocompatibility. In this study, an optical waveguide sensor integrating a carbon fiber layer, fully constraining stretching deformation, partly constraining pressing deformation, and allowing bending deformation, was proposed. The sensitivity of the proposed sensor is three times higher than that of the sensor without a carbon fiber layer, and good repeatability is maintained. We also attached the proposed sensor to the upper limb to monitor grip force, and the sensor signal showed a good correlation with grip force (the R-squared of the quadratic polynomial fitting was 0.9827) and showed a linear relationship when the grip force was greater than 10 N (the Rsquared of the linear fitting was 0.9523). The proposed sensor has the potential for applications in recognizing the intention of human movement to help the amputees control the prostheses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.