This study investigated the rebound behavior of SiO 2 particles normally impacting a planar surface under different temperature conditions. The system has been characterized for an aerosol inlet temperature range of 20-190 °C, flow velocities of 0-20 ms , and an impaction surface temperature range of 20-140 °C. For the first time, while keeping the same temperature gradient from the high-to low-temperature regions, the influences of varying temperature on the rebound behavior of SiO 2 particles normally impacting a plane surface were examined. At increased temperatures, the plastic deformation increases and the coefficient of restitution reduces. The critical velocity is between 0.542 and 0.546 m/s under condition 1 (the carrier gas temperature (T g ) and the impaction surface temperature (T W ) remain at room temperature of 20 °C), which increases to between 0.829 and 0.847 m/s under condition 4 (T g and T W remain at temperatures of 190 °C and 140 °C, respectively). The experimental results show that the critical velocity increases with increasing temperature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.