Abstract-A dynamical model based on three coupled ordinary differential equations is introduced which is capable of generating realistic synthetic electrocardiogram (ECG) signals. The operator can specify the mean and standard deviation of the heart rate, the morphology of the PQRST cycle, and the power spectrum of the RR tachogram. In particular, both respiratory sinus arrhythmia at the high frequencies (HFs) and Mayer waves at the low frequencies (LFs) together with the LF/HF ratio are incorporated in the model. Much of the beat-to-beat variation in morphology and timing of the human ECG, including QT dispersion and R-peak amplitude modulation are shown to result. This model may be employed to assess biomedical signal processing techniques which are used to compute clinical statistics from the ECG.
SummaryBackgroundStudies evaluating titration of antihypertensive medication using self-monitoring give contradictory findings and the precise place of telemonitoring over self-monitoring alone is unclear. The TASMINH4 trial aimed to assess the efficacy of self-monitored blood pressure, with or without telemonitoring, for antihypertensive titration in primary care, compared with usual care.MethodsThis study was a parallel randomised controlled trial done in 142 general practices in the UK, and included hypertensive patients older than 35 years, with blood pressure higher than 140/90 mm Hg, who were willing to self-monitor their blood pressure. Patients were randomly assigned (1:1:1) to self-monitoring blood pressure (self-montoring group), to self-monitoring blood pressure with telemonitoring (telemonitoring group), or to usual care (clinic blood pressure; usual care group). Randomisation was by a secure web-based system. Neither participants nor investigators were masked to group assignment. The primary outcome was clinic measured systolic blood pressure at 12 months from randomisation. Primary analysis was of available cases. The trial is registered with ISRCTN, number ISRCTN 83571366.Findings1182 participants were randomly assigned to the self-monitoring group (n=395), the telemonitoring group (n=393), or the usual care group (n=394), of whom 1003 (85%) were included in the primary analysis. After 12 months, systolic blood pressure was lower in both intervention groups compared with usual care (self-monitoring, 137·0 [SD 16·7] mm Hg and telemonitoring, 136·0 [16·1] mm Hg vs usual care, 140·4 [16·5]; adjusted mean differences vs usual care: self-monitoring alone, −3·5 mm Hg [95% CI −5·8 to −1·2]; telemonitoring, −4·7 mm Hg [–7·0 to −2·4]). No difference between the self-monitoring and telemonitoring groups was recorded (adjusted mean difference −1·2 mm Hg [95% CI −3·5 to 1·2]). Results were similar in sensitivity analyses including multiple imputation. Adverse events were similar between all three groups.InterpretationSelf-monitoring, with or without telemonitoring, when used by general practitioners to titrate antihypertensive medication in individuals with poorly controlled blood pressure, leads to significantly lower blood pressure than titration guided by clinic readings. With most general practitioners and many patients using self-monitoring, it could become the cornerstone of hypertension management in primary care.FundingNational Institute for Health Research via Programme Grant for Applied Health Research (RP-PG-1209-10051), Professorship to RJM (NIHR-RP-R2-12-015), Oxford Collaboration for Leadership in Applied Health Research and Care, and Omron Healthcare UK.
Abstract-Spectral estimates of heart rate variability (HRV) often involve the use of techniques such as the fast Fourier transform (FFT), which require an evenly sampled time series. HRV is calculated from the variations in the beat-to-beat (RR) interval timing of the cardiac cycle which are inherently irregularly spaced in time. In order to produce an evenly sampled time series prior to FFT-based spectral estimation, linear or cubic spline resampling is usually employed. In this paper, by using a realistic artificial RR interval generator, interpolation and resampling is shown to result in consistent over-estimations of the power spectral density (
Routinely recorded electrocardiograms (ECGs) are often corrupted by different types of artefacts and many efforts have been made to enhance their quality by reducing the noise or artefacts. This paper addresses the problem of removing noise and artefacts from ECGs using independent component analysis (ICA). An ICA algorithm is tested on three-channel ECG recordings taken from human subjects, mostly in the coronary care unit. Results are presented that show that ICA can detect and remove a variety of noise and artefact sources in these ECGs. One difficulty with the application of ICA is the determination of the order of the independent components. A new technique based on simple statistical parameters is proposed to solve this problem in this application. The developed technique is successfully applied to the ECG data and offers potential for online processing of ECG using ICA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.