Background: The COVID-19 pandemic has resulted in worldwide morbidity at unprecedented scale. Troponin elevation is a frequent laboratory finding in hospitalized patients with the disease, and may reflect direct vascular injury or non-specific supply-demand imbalance. In this work, we assessed the correlation between different ranges of Troponin elevation, Electrocardiographic (ECG) abnormalities, and mortality.Methods: We retrospectively studied 204 consecutive patients hospitalized at NYU Langone Health with COVID-19. Serial ECG tracings were evaluated in conjunction with laboratory data including Troponin. Mortality was analyzed in respect to the degree of Troponin elevation and the presence of ECG changes including ST elevation, ST depression or T wave inversion.Results: Mortality increased in parallel with increase in Troponin elevation groups and reached 60% when Troponin was >1 ng/ml. In patients with mild Troponin rise (0.05–1.00 ng/ml) the presence of ECG abnormality and particularly T wave inversions resulted in significantly greater mortality.Conclusion: ECG repolarization abnormalities may represent a marker of clinical severity in patients with mild elevation in Troponin values. This finding can be used to enhance risk stratification in patients hospitalized with COVID-19.
Cardiac resynchronization therapy (CRT) is an effective intervention in selected patients with moderate-to-severe heart failure with reduced ejection fraction and abnormal left ventricular activation time. The non-response rate of approximately 30% has remained nearly unchanged since this therapy was introduced 25 years ago. While intracardiac mapping is widely used for diagnosis and guidance of therapy in patients with tachyarrhythmia, its application in characterization of the electrical substrate to elucidate the mechanisms involved in CRT response remain anecdotal. In the present review, we describe the traditional determinants of CRT response before presenting novel non-invasive techniques used for CRT optimization. We discuss efforts to identify the target electrical substrate to guide the deployment of pacing electrodes during the operative procedure. Non-invasive body surface mapping technologies such as ECG imaging or ECG belt enables prediction of acute and chronic CRT response. While electrical dyssynchrony parameters provide high predictive accuracy for CRT response when obtained during intrinsic conduction, their predictive value is less when acquired during CRT or LV-pacing. KEY MESSAGES Classic predictors of CRT response are female gender, NYHA class III, left ventricular ejection fraction !25%, QRS duration !150 ms and estimated glomerular filtration rate !60 mL/min. ECG-imaging is a comprehensive non-invasive mapping system which allows to express the amount of electrical asynchrony of a CRT candidate. Non-invasive body surface mapping technologies enables excellent prediction of acute and chronic CRT response before implantation. When performed during CRT or LV-pacing, the added value of these mapping systems remains unclear.
Introduction Prior studies have shown that addition of posterior wall isolation (PWI) may reduce atrial fibrillation recurrence in patients with persistent atrial fibrillation. No data on PWI in paroxysmal AF (pAF) patients with normal left atrial voltage is available, to date. Objective This study sought to evaluate the efficacy of PWI in addition to pulmonary vein isolation (PVI) in patients presenting with pAF and normal left atrial voltage. Methods Consecutive patient registry analysis was performed on all patients with pAF and normal left atrial voltage undergoing initial radiofrequency ablation from November 1, 2018 to November 15, 2019. Primary endpoint was recurrence of atrial arrhythmia including AF, atrial tachycardia (AT), or atrial flutter (AFL). Results A total of 321 patients were studied, 214 in the PVI group and 107 in the PWI + PVI group. Recurrence of any atrial arrhythmia occurred in 18.2% of patients in the PVI group and 16.8% in the PVI + PWI cohort (p = 0.58). At 1 year, recurrence was 14.0% in the PVI group and 15.0% in the PWI + PVI group (p = 0.96). There was a lower AT/AFL recurrence in the PVI + PWI group, not reaching significance (3.7% in the PWI + PVI group vs. 7.9% in PVI group, p = 0.31). Need for carina lesions predicted recurrence in the PVI‐only group. Conclusions Addition of PWI to PVI in pAF patients undergoing their first ablation did not reduce the frequency of atrial arrhythmia recurrence. This warrants further study in a prospective trial.
Conducted energy weapon (commonly known as TASER) discharge in patients with implantable cardioverter-defibrillators is known to cause electromagnetic interference and inappropriate ventricular fibrillation sensing without delivery of implantable cardioverter-defibrillators therapy during conducted energy weapon application. We report the first known case of conducted energy weapon discharge resulting in inappropriate implantable cardioverter-defibrillators therapy. ( Level of Difficulty: Beginner. )
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.