Background The pneumonia caused by the 2019 novel coronavirus (SARS-CoV-2, also called 2019-nCoV) recently break out in Wuhan, China, and was named as COVID-19. With the spread of the disease, similar cases have also been confirmed in other regions of China. We aimed to report the imaging and clinical characteristics of these patients infected with SARS-CoV-2 in Guangzhou, China. Methods All patients with laboratory-identified SARS-CoV-2 infection by real-time polymerase chain reaction (PCR) were collected between January 23, 2020, and February 4, 2020, in a designated hospital (Guangzhou Eighth People's Hospital). This analysis included 90 patients (39 men and 51 women; median age, 50 years (age range, 18-86 years). All the included SARS-CoV-2-infected patients underwent non-contrast enhanced chest computed tomography (CT). We analyzed the clinical characteristics of the patients, as well as the distribution characteristics, pattern, morphology, and accompanying manifestations of lung lesions. In addition, after 1-6 days (mean 3.5 days), follow-up chest CT images were evaluated to assess radiological evolution. Findings The majority of infected patients had a history of exposure in Wuhan or to infected patients and mostly presented with fever and cough. More than half of the patients presented bilateral, multifocal lung lesions, with peripheral distribution, and 53 (59%) patients had more than two lobes involved. Of all included patients, COVID-19 pneumonia presented with ground glass opacities in 65 (72%), consolidation in 12 (13%), crazy paving pattern in 11 (12%), interlobular thickening in 33 (37%), adjacent pleura thickening in 50 (56%), and linear opacities combined in 55 (61%). Pleural effusion, pericardial effusion, and lymphadenopathy were uncommon findings. In addition, baseline chest CT did not show any abnormalities in 21 patients (23%), but 3 patients presented bilateral ground glass opacities on the second CT after 3-4 days. Conclusion SARS-CoV-2 infection can be confirmed based on the patient's history, clinical manifestations, imaging characteristics, and laboratory tests. Chest CT examination plays an important role in the initial diagnosis of the novel coronavirus pneumonia. Multiple patchy ground glass opacities in bilateral multiple lobular with periphery distribution are typical chest CT imaging features of the COVID-19 pneumonia.
Background CC-Cruiser is an artificial intelligence (AI) platform developed for diagnosing childhood cataracts and providing risk stratification and treatment recommendations. The high accuracy of CC-Cruiser was previously validated using specific datasets. The objective of this study was to compare the diagnostic efficacy and treatment decision-making capacity between CC-Cruiser and ophthalmologists in real-world clinical settings. Methods This multicentre randomized controlled trial was performed in five ophthalmic clinics in different areas across China. Pediatric patients (aged ≤ 14 years) without a definitive diagnosis of cataracts or history of previous eye surgery were randomized (1:1) to receive a diagnosis and treatment recommendation from either CC-Cruiser or senior consultants (with over 5 years of clinical experience in pediatric ophthalmology). The experts who provided a gold standard diagnosis, and the investigators who performed slit-lamp photography and data analysis were blinded to the group assignments. The primary outcome was the diagnostic performance for childhood cataracts with reference to cataract experts' standards. The secondary outcomes included the evaluation of disease severity and treatment determination, the time required for the diagnosis, and patient satisfaction, which was determined by the mean rating. This trial is registered with ClinicalTrials.gov ( NCT03240848 ). Findings Between August 9, 2017 and May 25, 2018, 350 participants (700 eyes) were randomly assigned for diagnosis by CC-Cruiser (350 eyes) or senior consultants (350 eyes). The accuracies of cataract diagnosis and treatment determination were 87.4% and 70.8%, respectively, for CC-Cruiser, which were significantly lower than 99.1% and 96.7%, respectively, for senior consultants ( p < 0.001, OR = 0.06 [95% CI 0.02 to 0.19]; and p < 0.001, OR = 0.08 [95% CI 0.03 to 0.25], respectively). The mean time for receiving a diagnosis from CC-Cruiser was 2.79 min, which was significantly less than 8.53 min for senior consultants ( p < 0.001, mean difference 5.74 [95% CI 5.43 to 6.05]). The patients were satisfied with the overall medical service quality provided by CC-Cruiser, typically with its time-saving feature in cataract diagnosis. Interpretation CC-Cruiser exhibited less accurate performance comparing to senior consultants in diagnosing childhood cataracts and making treatment decisions. However, the medical service provided by CC-Cruiser was less time-consuming and achieved a high level of patient satisfaction. CC-Cruiser has the capacity to assist human doctors in clinical practice in its current state. Funding National Key R&D Program of China (2018YFC0116500) and the Key Research Plan for the National Natural Science Foundation of China in Cultivation P...
The torsional mode may provide more effective lens removal with a lower level of phacoemulsification time and energy.
The repair and regeneration of tissues using endogenous stem cells represents an ultimate goal in regenerative medicine. To our knowledge, human lens regeneration has not yet been demonstrated. Currently, the only treatment for cataracts, the leading cause of blindness worldwide, is to extract the cataractous lens and implant an artificial intraocular lens. However, this procedure poses notable risks of complications. Here we isolate lens epithelial stem/progenitor cells (LECs) in mammals and show that Pax6 and Bmi1 are required for LEC renewal. We design a surgical method of cataract removal that preserves endogenous LECs and achieves functional lens regeneration in rabbits and macaques, as well as in human infants with cataracts. Our method differs conceptually from current practice, as it preserves endogenous LECs and their natural environment maximally, and regenerates lenses with visual function. Our approach demonstrates a novel treatment strategy for cataracts and provides a new paradigm for tissue regeneration using endogenous stem cells.
No author has a financial or proprietary interest in any material or method mentioned.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.