Introduction Dental implant abutments play an important role in the health and aesthetics of soft and hard tissues around implants. Purpose To compare mechanical properties and marginal fit of prefabricated and customized dental implant abutments and provide references to evaluate the relationship between abutment choice and clinical indications. Methods Titanium abutments were randomly divided into prefabricated and customized abutments. Static and dynamic loads were applied according to ISO14801:2016. Mechanical properties, including fracture strength, fatigue strength, rotational torque value, and torque loss rate, were measured. The biological properties of the implant abutments were assessed using an internal marginal fit. The samples were sliced, and the internal marginal fit was examined using a scanning electron microscope before and after cyclic loading. The length of the tight contact was calculated at the level of the conical connection, lower internal connection, and screw threads. Microleakage was evaluated by immersing the samples in 1% methylene blue and measuring the absorbance. Results The fracture strengths of the prefabricated abutments were greater than those of the customized abutments before and after cyclic loading. The average fatigue strengths of the prefabricated and customized abutments were 350 and 300 N, respectively. The removal torque loss of the customized abutments was significantly greater than that of the prefabricated abutments. Significant differences were found in conical connection before loading, while the screw threads showed substantial differences between the two groups after loading. Microleakage in the customized abutments was significantly higher than that in the prefabricated abutments before and after loading. Conclusions Prefabricated abutments showed superior mechanical and biological properties compared with customized abutments in vitro, suggesting a greater risk of mechanical and biological complications occurring with the use of customized abutments. This study provides a reference for the clinical selection of implant abutments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.