Background and Objectives: Anterior cruciate ligament (ACL) tears are common injuries in the athletic population, and accordingly, ACL reconstruction (ACLR) is among the most common orthopedic surgical procedures performed in sports medicine. This study aims to compare the semitendinosus/gracilis (ST/G) and ACL hamstring grafts fixed using adjustable cortical suspension in both the femur and tibia (MAI) ACLR techniques. We aimed to compare the results of single-leg hop tests (SLHT) applied in different directions and limb symmetry indices (LSI) in athletes with a 6-month post-operative ACLR history. Materials and Methods: A retrospective cohort of 39 athletes from various sports branches who underwent MAI (n = 16) and ST/G (n = 23) ACLR techniques by the same surgeon were evaluated. The knee strength of the participants on the operated and non-operated sides was evaluated with five different SLHTs. The SLHT included the single hop for distance (SH), triple hop for distance (TH), crossover triple hop for distance (CH), medial side triple hop for distance (MSTH), and medial rotation (90°) hop for distance (MRH). Results: There was a significant improvement in the mean Lysholm, Tegner, and IKDC scores in the post-operative leg for both techniques (p < 0.05) compared to the pre-operative levels. When there was a difference between the SH of the operative and the non-operative legs in the ST/G technique (p < 0.05), there was no significant difference in the other hop distance for both ST/G and MAI (p > 0.05). There was no difference between the techniques regarding the LSI scores. Conclusions: The fact that our research revealed similar LSI rates of the SLHTs applied in different directions in the ST/G and MAI techniques assumes that the MAI technique can be an ACLR technique which can be functionally used in athletes.
This study compared the clinical outcomes of patients treated with described “modified all-inside” anterior cruciate ligament reconstruction (ACLR) technique with those of patients treated with suspensory femoral fixation and a bioabsorbable tibial interference screw with the ACLR technique. From 2017 to 2019, 98 patients who underwent ACLR surgery by two surgeons using either of the techniques were included in this study. Patients in group 1 were treated with the “modified all-inside” ACLR technique. In this technique, only the semitendinosus tendon was harvested as a four-strand graft and fixed to the tibia and femur with suspensory buttons. Patients in group 2 were treated with suspensory femoral fixation and a bioabsorbable tibial interference screw ACL reconstruction technique. Patients' functional outcomes were evaluated by the Lysholm score, Tegner activity scale, and International Knee Documentation Committee (IKDC) subjective score. Postoperative knee stability of the patients was evaluated using the Lachman test and the pivot-shift test. The mean ages of the patients were 31.1 (16–55) and 28.7 (18–48) years in groups 1 and 2, respectively. The average follow-up durations were 26 (20–30) and 25.9 (22–30) months for both groups. There was no significant difference between the preoperative and postoperative Lysholm's score, Tegner's activity score, and IKDC subjective score in groups 1 and 2. There were no major complications or reruptures in either group. ACLR incorporating the “modified all-inside” ACLR technique obtained significant clinical outcomes compared to ACLR with a suspensory femoral fixation and a bioabsorbable tibial interference screw.
IntroductionImplants used in orthopedic surgery can be colonized by bacteria that form biofilm layers complicating treatment. We aimed to determine titanium implants' antibacterial and biofilm-degrading properties when coated with sodium borate (NaB) and calcium borate (CaB) minerals. MethodsWe analyzed twenty-four different implants. Three implants were not coated, three were coated with only a carrier polymer (alginate), and eighteen were coated with either CaB or NaB at different concentrations. The implants were incubated with Staphylococcus aureus, and then the bacterial colonies were enumerated. ResultsThe highest microbial load was observed on the implant coated with alginate (1000 colony-forming units [CFU]/mL). The implant without coating contained a microbial load of 420 CFU/mL. The microbial loads of the implants coated with 0.75 mg/mL CaB or 0.25, 0.5, and 0.75 mg/mL NaB (100, 200, 0, and 0 CFU/mL, respectively) were lower than that of the implant without coating. No biofilm formation was observed on implant surfaces coated with 0.5 mg/mL NaB, 0.75 mg/mL NaB, or 0.75 mg/mL CaB; biofilm formation was observed on the implant without coating and alginate-coated implants surfaces. ConclusionAt high concentrations, borate minerals (NaB and CaB) have a potent antibacterial effect on colonization and biofilm formation on the implant surface. These elements may be used in implant coating in the future because of their potential antibacterial effects.
Introduction:In this retrospective study, it was aimed to evaluate the correlation between operative treatment results and clinical and radiological findings of tibial plateau fractures. Patients and Methods: Between 1996 and 2006, 33 knees were operated for tibia plateau fracture of 32 patients. 29 patients were male and 3 were female. Only 3 cases (9.99%) were open tibial plateau fractures. The mean age was 45 years. Fractures classified using the Schatzker classification were: 17 (52%) type 1, 12 (12%) type 2, 9 (27%) type 5 and 6 (9%) type 6. Patients following the period were at least 44 weeks and maximum 480 weeks (mean 60 weeks). Results: The results of 33 patients were determined by the clinical and radiological system of Rasmussen. According to clinical findings, 17 cases were excellent, 9 were good, 6 were medium and 1 was poor. According to the radiological findings, 9 cases were excellent, 16 were good, 6 were medium and 2 were bad. The difference between clinical and radiological findings was analyzed with Pearson core analysis and statistically significant (p < 0.005). Comparison was made according to the time between injury and operation and no statistically significant difference was found (p > 0.005). The analyzes of the grade of fracture and the degree of fracture were statistically significant (p < 0.005). 42.4% of all patients had meniscus injury. Therefore, arthroscopy should be used with surgery. Conclusion: Anatomic reduction, rigid fixation of the joint and early mobilization can reduce complications and improve the function of the knee joint in tibial plateau fractures.
Background and Objectives: Anterior cruciate ligament (ACL) injuries are common injuries with a high incidence among people with high physical activity levels. Therefore, ACL reconstruction (ACLR) is one of the most common surgical procedures performed in sports medicine. This study aims to compare the pre- and 6-month post-operative isokinetic knee strengths in healthy (HK) and ACL knees of patients who underwent semitendinous/gracilis (ST/G) ACLR. Materials and Methods: A retrospective cohort of 21 recreational athletes who underwent ST/G ACLR by the same surgeon were evaluated. The pre- and 6-month post-operative isokinetic knee extension (Ex) and flexion (Flx) strengths of the HK and ACLR patients were evaluated in a series consisting of three different angular velocities (60, 180 and 240°/s). Of all the findings, peak torque (PT) and hamstring/quadriceps (H/Q) parameters were evaluated. Results: There was a significant improvement in post-operative Lysholm, Tegner and IKDC scores compared to pre-operative scores (p < 0.05). There were significant differences in pre-operative and post-operative knee Ex and Flx strengths at angular velocities of 60°, 180° and 240°/s in both the ACLR and HK groups (p < 0.001). There was no significance at 240°/s Flx for ACLR (p > 0.05). As for H/Q ratios, there was a significant difference between pre- and post-operative values only at 60°/s angular velocity in both ACLR and HC (p < 0.005). Conclusions: The pre-operative and 6-month post-operative results of the ST/G ACLR showed that there was a high level of recovery, particularly in quadriceps strength, while the increase in strength was less in the hamstring. The significance observed at 60°/s in H/Q ratios was within normal ranges. It can be argued that the ST/G ACLR method is feasible for people with high physical activity levels and for athletes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.