The mean corpuscular volume (MCV) of peripheral blood mononuclear cells (PBMCs) was determined by Coulter Counter, and data were used to calculate the intracellular drug concentrations. A total of 574 PBMC samples were collected from 190 patients. The MCV was 282.9 fl (minimum, 207.0; maximum, 354.6), with a standard deviation of 8.8%. Previous reports have often used a fixed value of 400 fl for the MCV, which may result in artificially low estimates of the intracellular concentrations of antivirals.
A new method using high-performance liquid chromatography coupled with photo diode array detection was developed and validated for the quantification of plasma concentrations of the human immunodeficiency syndrome integrase inhibitor raltegravir (RGV), the new nonnucleoside reverse transcriptase inhibitor etravirine (ETV), and 11 other antiretroviral agents: ritonavir, atazanavir, lopinavir, nevirapine, efavirenz, saquinavir, indinavir, nelfinavir, and its metabolite M-8, amprenavir, and darunavir. A simple solid phase extraction procedure was applied to 500 microL aliquots of plasma, and chromatographic separation of the drugs and internal standard (quinoxaline) was achieved with a gradient (acetonitrile and phosphate buffer) on an C-18 reverse-phase analytical column with a 28-minute analytical run time. Calibration curves were optimized according to expected ranges of drug concentrations in patients, and the coefficient of determination (r) was higher than 0.998 for all analytes. Mean intraday and interday precisions (percent relative SD) for all compounds were 3.67% and 6.39%, respectively, and mean accuracy (percent deviation from nominal concentration) was -1.17%. Extraction recovery ranged within 75% and 83% for all drugs analyzed. The solid phase extraction and high-performance liquid chromatography coupled with photo diode array method described allow a specific, sensitive, and reliable simultaneous determination of RGV, ETV, and 11 antiretroviral agents in plasma by a single assay. Good extraction efficiency and low limit of quantification make this a suitable method for use in clinical trials and for therapeutic drug monitoring of RGV, protease inhibitors, and nonnucleoside reverse transcriptase inhibitors, including ETV.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.