Optical microsurgery of the retinal pigment epithelium (RPE) requires reliable real-time dosimetry to prevent unwanted overexposure of the neuroretina. The system used in this experiment implements optical coherence tomography (OCT) to detect the intentional elimination of RPE cells. We evaluated the performance of OCT dosimetry in terms of its ability to detect RPE cell damage caused by microsecond laser pulses of varying duration. Therefore, ex-vivo porcine RPE choroid sclera explants were embedded in an artificial eye and exposed to single laser pulses of 2–20 µs duration (wavelength: 532 nm, exposure area: 120 × 120 µm2, intensity modulation factor: 1.3). Simultaneously, time-resolved OCT M-scans were recorded (central wavelength: 870 nm, scan rate: 33 kHz). Post-irradiation, RPE cell damage was quantified using a calcein-AM viability assay and compared with an OCT-dosimetry algorithm. The results of our experiments show that the OCT-based analysis successfully predicts RPE cell damage. At its optimal operating point, the algorithm achieved a sensitivity of 89% and specificity of 94% for pulses of 6 µs duration and demonstrated the ability to precisely control radiant exposure of a wide range of pulse durations towards selective real-time laser microsurgery.
Selective retina therapy (SRT) is a short pulse (µs-regime) alternative to conventional laser photocoagulation (LPC) for treatment of retinal diseases. LPC leads to collateral damage of retinal layers adjacent to the retinal pigment epithelium (RPE), including healthy, non-regenerative photoreceptors due to the high thermal load, whereas in SRT, RPE cells are destroyed by microbubbles without damaging the neuronal retina. A novel experimental SRT laser operating at 532 nm wavelength can deliver 2 -20 μs pulse sequences. Its tight integration into an upgraded diagnostic SPECTRALIS system combines beam control for treatment planning with real-time optical coherence tomography (OCT) overexposure protection of the photoreceptors. This "Spectralis Centaurus" system, was built and preliminary tested on porcine ex-vivo samples, reaching an unprecedented accuracy with unique planning and follow-up capabilities for upcoming clinical cellular level micro-surgery. The combination of OCT with SRT selectively limits cell death to the RPE by precisely controlling energy deposition while optically monitoring tissue response.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.