In rheumatoid arthritis, the joints of the lower extremities are almost always affected. This is most conspicuous in the knee joint. In rheumatics, inflammatory osteoarthritis manifests itself comparably earlier than in patients with osteoarthritis. The focus of attention was primarily on the synovia with its destruction process and secondary changes. Now, driven by experimental research, dendritic cells and fibroblasts and molecular features are moving into the clinician’s field of vision. Even in joints that appear to be in remission with no swelling or pain, the activity of these cells leads to changes in the capsule-ligaments. The complex deformities and instabilities caused by this, in conjunction with atrophy of the inter-articular musculature, have an impact on the activities of daily life (ADL). If these biomechanical aspects of the knee joint are not taken into account early on in therapy, the frequency of primary and secondary surgical treatment increases. The timely recognition of biomechanical pathologies and consistent treatment can contribute to improving the patient situation in addition to adequate medication therapy.
Background: Patients with an inflammatory disease frequently develop chronic angiopathy of the capillaries. Due to this pathology, there is an increased rate of complications in lower extremity surgical procedures. It is not uncommon for microangiopathic wound healing disorders to cause deep infections and fistulas, which lead to prolonged courses and hospitalizations. In addition, adhesions and ossifications of the contractile elements occur regularly. This sometimes results in serious limitations of the mobility of the patients. The study aims to present the results of a combination of vacuum and physical therapy. Patient and methods: A retrospective study of six patients with systemic sclerosis undergoing joint-related procedures of the lower extremity between 2015 and 2020 was performed. In addition to characterization of the patients and therapy, special attention was paid to cutaneous wound healing, affection of the fascia and displacement layers, and sclerosis of the muscle and tendon insertion. Results: The characterized structures (skin, tendon, fascia) show pathological changes at the microangiopathic level, which are associated with delayed healing and less physical capacity. Early suture removal regularly results in secondary scar dehiscence. With a stage-adapted vacuum therapy with sanitation of the deep structures and later on a dermal vacuum system, healing with simultaneous mobilization of the patients could be achieved in our patient cohort. Conclusion: In the case of necessary interventions on the lower extremity, such as trauma surgery, additional decongestive measures in the sense of regular and sustained lymphatic therapy and adapted physiotherapy are indispensable.
The wrist is among the predilection sites of over 90% of cases of rheumatoid arthritis (RA). In advanced cases, total wrist arthroplasty (TWA) is an alternative to arthrodesis. The aim of this study is to present the long-term results of the modular physiological wrist prosthesis (MPW®) and to match them in context with the results of a standard population survey. In a retrospective study with follow-up, patients with an MPW® endoprosthesis were evaluated concerning the clinical and radiological outcome, complications were reviewed (incidence and type), and conversion to wrist fusion was assessed. Patient function measurements included the Mayo wrist score, the patient-specific wrist test, and therefore the DASH score (arm, shoulder, and hand). Thirty-four MPW® wrist prostheses were implanted in 32 patients, including thirty primary implantations and four changes of the type of the endoprosthesis. Sixteen patients (18 prostheses) underwent clinical and radiological follow-up. The average follow-up time was 8.5 years (1 to 16). Poor results of the MPW prosthesis are caused by the issues of balancing with luxation and increased PE wear. Salvage procedures included revision of the TWA or fusion. In successful cases, the flexion and extension movement averaged 40 degrees. The grip force was around 2.5 kg. The common DASH score was 79 points, with limited and problematic joints of the upper extremity. The MPW wrist prosthesis offered good pain relief and functional movement in over 80% of cases. The issues of dislocation and increased PE wear prevent better long-term results, as do the joints affected. A follow-up study with fittings under a contemporary anti-rheumatic therapy with biologicals suggests increasing score results. Type of study/level of evidence: Case series, IV.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.