This work describes the replacement of Tissue Phantom Ratio (TPR) measurements with beam profile flatness measurements to determine photon beam quality during routine quality assurance (QA) measurements. To achieve this, a relationship was derived between the existing TPR15/5 energy metric and beam flatness, to provide baseline values and clinically relevant tolerances. The beam quality was varied around two nominal beam energy values for four matched Elekta linear accelerators (linacs) by varying the bending magnet currents and reoptimizing the beam. For each adjusted beam quality the TPR15/5 was measured using an ionization chamber and Solid Water phantom. Two metrics of beam flatness were evaluated using two identical commercial ionization chamber arrays. A linear relationship was found between TPR15/5 and both metrics of flatness, for both nominal energies and on all linacs. Baseline diagonal flatness (FDN) values were measured to be 103.0% (ranging from 102.5% to 103.8%) for 6 MV and 102.7% (ranging from 102.6% to 102.8%) for 10 MV across all four linacs. Clinically acceptable tolerances of ±2% for 6 MV, and ±2% for 10 MV, were derived to equate to the current TPR15/5 clinical tolerance of ±0.5%. Small variations in the baseline diagonal flatness values were observed between ionization chamber arrays; however, the rate of change of TPR15/5 with diagonal flatness was found to remain within experimental uncertainty. Measurements of beam flatness were shown to display an increased sensitivity to variations in the beam quality when compared to TPR measurements. This effect is amplified for higher nominal energy photons. The derivation of clinical baselines and associated tolerances has allowed this method to be incorporated into routine QA, streamlining the process whilst also increasing versatility. In addition, the effect of beam adjustment can be observed in real time, allowing increased practicality during corrective and preventive maintenance interventions.PACS number: 87.56.Fc
The preoperative experience can cause significant anxiety for both pediatric patients and their parents in the lead up to a surgical procedure. Pediatric anxiety in a preoperative setting has been shown to have significant negative downstream effects on the clinical outcomes of children and the healthcare system as a whole. Studies have found that preoperative parental anxiety has significant negative effects on children, regarding anxiety and emotional response. Therefore, interventions for parental preoperative anxiety are important to reduce the child’s anxiety. This review provides a brief overview of a broad range of strategies used to alleviate parental anxiety in a preoperative setting. Preoperative education, play-based interventions, music therapy, the presence of parents at induction of anesthesia, and integrative preoperative preparation programs have all demonstrated some evidence for reducing parental preoperative anxiety. The ultimate goal of using interventions for parental preoperative anxiety is to equip healthcare systems to better support families and optimize the perioperative outcomes of children.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.