Background: ABO-incompatible (ABOi) living donor liver transplantation (LDLT) has been proposed to compensate for donor shortage. To date, few studies have reported detailed ABOi LDLT results in large series of pediatric patients. C4d complement deposition in graft capillaries has been reported to be associated with antibody-mediated rejection in solid organ transplantation. Methods: A retrospective case–control study was conducted, comparing clinical outcomes of each of 34 consecutive pediatric ABOi LDLT recipients with those of 2 non-ABOi pairs (n = 68), matched according to pre-transplant diagnostic criteria, age, and date of transplantation. In addition, we studied the C4d immunostaining pattern in 22 ABOi and in 36 non-ABOi recipients whose liver biopsy was performed within the first 4 post-transplant weeks for suspected acute rejection. Results: The incidence of biliary complications was higher in ABOi recipients (p < 0.05), as were the incidence of acute humoral rejection (p < 0.01) and the incidence of retransplantation (p < 0.05). All children who required retransplantation were older than 1 year at the time of ABOi LDLT. Positive C4d immunostaining was observed in 13/22 (59%) ABOi recipients versus 3/36 (8.3%) non-ABOi recipients (p < 0.0001). Conclusions: ABOi LDLT is a feasible option for pediatric end-stage liver disease but carries increased risks for the recipient, especially for children older than 1 year, even with a specific preparation protocol. C4d immunostaining may be a hallmark of acute humoral rejection in ABOi liver transplantation.
Purpose/background The aim of this study was to evaluate the short and midterm results of aortic coarctation (AoCo) stenting in an adolescent and adult population. Methods All patients with a AoCo older than 14 years treated by stent placement between December 2000 and November 2016 were included in this study. Twenty-eight patients with an invasive peak systolic pressure gradient >20 mmHg were identified. Number of redilations, non-invasive systolic blood pressure, peak systolic pressure gradient, antihypertensive medication intake, claudication status and complications were evaluated. Results Twenty-two covered and 6 uncovered stents were successfully placed. Peak systolic pressure gradient decreased immediately after stenting from a mean of 32 mmHg to 0 mmHg (± 7 mmHg). Mean AoCo diameter increased from 8 tot 16 mm (± 4 mm). Peripheral arterial injury was seen in 2 patients (7.1%). The mean follow-up time was 60 ± 49 months. Redilation of the stent was required in 4 patients, 2 to accommodate for growth and 2 for restenosis. Six (35%) patients could stop all antihypertensive medication. All claudicants (6/28) became and remained asymptomatic after surgery and during their follow-up. No aneurysms, stent fractures or dissections were noticed. There were 2 stent migrations during the first procedure with only 1 needing additional stent placement. Conclusion Aortic coarctation stenting is a safe and effective treatment that significantly reduces the peak systolic pressure gradient. Antihypertensive medication can be reduced, and increase of walking distance in claudicants can be obtained. Younger patients may need more frequent reinterventions to accommodate for growth.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.