IntroductionAcute aortic dissection type A (AADA) is associated with high perioperative morbidity and mortality. A novel non-covered hybrid prosthesis (Ascyrus Medical Dissection Stent (AMDS) Hybrid Prosthesis, Cryolife/Jotec, Hechingen, Germany) can be easily implanted to stabilize the true lumen (TL), improve remodeling, and preserve organ perfusion. Although developed for implantation in aortic zone 0, occasionally, partial replacement of the aortic arch and further distal implantation of AMDS may appear favorable. Implantation of AMDS with anastomosis line beyond zone 0 has not been described yet.Materials and MethodsBetween 08/2019 and 12/2020, a total of n = 97 patients were treated due to AADA at a single University hospital. Of those, n = 28 received an AMDS hybrid prosthesis, of whom in eight patients, due to intraoperative finding the distal anastomosis line was placed distal to the brachiocephalic trunk. Three patients had AMDS implantation in zone I and four were treated by implantation of the prostheses in zone II, and one patient had the implantation performed in zone III. Clinical outcome and the development of a proportional area of TL and false lumen (FL) at defined levels of the thoracic aorta were analyzed.ResultsNone of the surviving patients (87.5%) showed signs of clinical malperfusion (i.e., stroke, spinal cord injury, and need for dialysis). A postoperative CT scan showed an open TL in all patients. The proportion of TL with respect to total aortic diameter (TL+FL) was postoperatively significantly higher in zone III (p = 0.016) and at the level of T11 (p = 0.009). The mean area of TL+FL was comparable between pre- and postoperative CT-scan (p = n.s.). One patient with preoperative resuscitation died of multiple organ failure on extracorporeal life support on postoperative day 3.ConclusionImplantation of AMDS can be safely performed in patients who need partial replacement of the aortic arch beyond zone 0. The advantages of the AMDS can be combined with those of the total arch repair (remodeling of the arch and prevention of TL collapse) without the possible disadvantages (risk of spinal cord injury).
Prosthesis infection after aortic surgery is a critical complication that most commonly requires surgical treatment with removal of the infected material. In this video tutorial, we remove a novel nitinol wire braided stent. It was introduced to stabilize the true lumen and prevent distal anastomotic new entry. Both the stent type and surgical approach were new and therefore constituted a major challenge. Despite these issues, removal with bilateral subclavian and femoral cannulation under hypothermic circulatory arrest proved successful.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.