Although cardiac output (CO) by pulmonary artery catheterization (PAC) has been an important guideline in clinical management for more than four decades, some studies have questioned the clinical efficacy of CO in certain patient populations. Further, the use of CO by PAC has been linked to numerous complications including dysrhythmia, infection, rupture of pulmonary artery, injury to adjacent arteries, embolization, pulmonary infarction, cardiac valvular damage, pericardial effusion, and intracardiac catheter knotting. The use of PAC has been steadily declining over the past two decades. Minimally invasive and noninvasive CO monitoring have been studied in the past two decades with some evidence of efficacy. Several different devices based on pulse contour analysis are available currently, including the uncalibrated FloTrac/Vigileo system and the calibrated PiCCO and LiDCO systems. The pressure-recording analytical method (PRAM) system requires only an arterial line and is commercially available as the MostCare system. Transesophageal echocardiography (TEE) can measure CO by non-Doppler- or Doppler-based methods. The partial CO2 rebreathing technique, another method to measure CO, is marketed by Novametrix Medical Systems as the NICO system. Thoracic electrical bioimpedance (TEB) and electric bioreactance (EB) are totally noninvasive CO monitoring. Nexfin HD and the newer ClearSight systems are examples of noninvasive CO monitoring devices currently being marketed by Edwards Lifesciences. The developing focus in CO monitoring devices appears to be shifting to tissue perfusion and microcirculatory flow and aimed more at markers that indicate the effectiveness of circulatory and microcirculatory resuscitations.
The increase of interleukin-4 (IL-4) level in tumor environment and the up-regulation of IL-4 receptor (IL-4R) on tumor cells have been long observed. However, their significance for tumor development has not been investigated. Here, we found that endogenous IL-4 promotes tumor growth because neutralizing IL-4 by 11B11 monoclonal antibody (mAb) significantly delayed the growth of MCA205 fibrosarcoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with đź’™ for researchers
Part of the Research Solutions Family.