Background-Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. Methods and Results-At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9Ϯ10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. Conclusion-These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.
Assuming that the 21-mm valve holder in which all the tested prostheses were accommodated is comparable with a defined aortic valve size, this hydrodynamic evaluation model allowed us to compare the efficiency of currently available valve prostheses, and among these, the SJM Regent and the Sorin Bicarbon Slimline exhibited the best performances.
At intermediate follow-up, the Biocor prosthesis in the mitral position showed excellent results in terms of valve durability when compared with other second-generation tissue valves.
Aims
A global outbreak of Mycobacterium chimaera infections following cardiac surgery and linked to contaminated heater-cooler units (HCUs) is currently ongoing. Neither the status of this outbreak in Italy nor the mitigation strategies adopted by adult cardiac surgery units (ACSUs) are currently known. In 2017, the Italian Society of Cardiac Surgery launched a national survey among the Italian ACSU to shed some light on this issue.
Methods
In Italy, there are 90 ACSUs across 20 regions. From May to November 2017, these ACSUs were surveyed collecting data on patients diagnosed with MC infections, ACSU workload, HCU models in use and control measures adopted in the operatory room.
Results
The response rate was 87.8%. The median number of cardiac procedures at each ACSU was 450/year [interquartile range (IQR) 350–650 procedures/year], and nationally, the number of procedures/year exceeded 40k. In Italy, seven patients with M. chimaera infections following cardiac procedures have been reported since 2015: all had aortic or valvular surgery as the first procedure; the median latency between the first operation and the infection was 2 years (IQR 2–3.25). Mortality for patients requiring redo cardiac surgery was 50%. M. chimaera infections risk was 0.4–1 patient every 1000 cardiac procedures. The most common HCU model in Italy is the 3T HCU (70.9%). The most common control measures adopted included implementing new HCU disinfection protocols, using sterile or filtrated water in the HCU and displacing HCU fans away from the patient: HCU replacement and microbiology testing were instead infrequent.
Conclusion
In Italy, the risk of contracting M. chimaera infections and the mortality reported are in line with other European countries, but significant heterogeneity exists on the mitigation strategies adopted to prevent further M. chimaera inoculations, suggesting the development of national guidelines.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.