Approximately 19 % of patients in our series showed simultaneous high PD-1/PD-L1 immunoscores, and were the best candidates for receiving targeted anti-PD-1/PD-L1 immunotherapy, as determined using a tissue based rationale.
Low-grade neuroepithelial tumors (LGNT) show a broad histopathological spectrum and may be difficult to classify using current World Health Organization (WHO) criteria. A 57-year-old man came to medical attention because of headaches. The patient medical history was otherwise unremarkable. Magnetic resonance imaging (MRI) revealed a 2.5 cm lesion, partially cystic, with an increased signal on T2-weighted imaging, located in the right frontal lobe. The patient underwent right frontal craniotomy and the surgical specimen was entirely evaluated. Microscopic examination showed a tumor arranged predominantly in sheets and nests, with an infiltrative growth pattern and oligodendroglioma-like appearance. Tumor cells were round to oval with cytoplasmic clearing, hyperchromatic nuclei and inconspicuous nucleoli. Only one mitosis was identified. Necrosis was absent. Differential diagnostic considerations included oligodendroglioma, clear cell ependymoma, polymorphous low-grade neuroepithelial tumor of the young (PLNTY) and long-term epilepsy-associated tumor with clear cell morphology. Neoplastic cells showed positivity for glial fibrillary acidic protein (GFAP), oligodendrocyte transcription factor 2 (OLIG2), α-thalasemia X-linked mental retardation syndrome (ATRX) (retained nuclear expression) and CD34. Epithelial membrane antigen (EMA), neuronal nuclear antigen, microtubule-associated protein-2e, cyclo-oxygenase-2, chromogranin A and isocitrate dehydrogenase 1 (IDH1) (R132H) were negative. Ki-67 labeling index was 2-3%. Molecular analysis identified neither IDH1/IDH2 mutations nor 1p19q codeletion. Rapidly accelerated fibrosarcoma homolog B1 (BRAF) V600E mutation was also absent by both molecular and immunohistochemical testing. Polymerase chain reaction analysis revealed the presence of fibroblast growth factor receptor 3 (FGFR3)-transforming acidic coiled-coil (TACC) fusion. Taken together, the morphological, immunohistochemical and molecular findings supported the final diagnosis of PLNTY.
Triple-negative breast carcinomas constitute a wide spectrum of lesions, mostly being highly aggressive. Nevertheless, some special histologic subtypes can have low malignant potential. The purpose of the present paper is to review diagnostic criteria and prognostic parameters of breast neoplasms of special histotypes. Specifically, adenoid cystic carcinoma, adenomyoepithelioma, acinic cell carcinoma, mucoepidermoid carcinoma, tall cell carcinoma with reverse polarity, and secretory carcinoma will be discussed. For each tumour, definition and morphological and molecular features, together with prognostic parameters, will be presented. Paradigmatic cases will be illustrated.
Introduction:Whole-slide imaging (WSI) technology can be used for primary diagnosis and consultation, including intraoperative (IO) frozen section (FS). We aimed to implement and validate a digital system for the FS evaluation of cancer and transplant specimens following recommendations of the College of American Pathologists.Materials and Methods:FS cases were routinely scanned at ×20 employing the “Navigo” scanner system. IO diagnoses using glass versus digital slides after a 3-week washout period were recorded. Intraobserver concordance was evaluated using accuracy rate and kappa statistics. Feasibility of WSI diagnoses was assessed by the way of sensitivity, specificity, as well as positive and negative predictive values. Participants also completed a survey denoting scan time, time spent viewing cases, preference for glass versus WSI, image quality, interface experience, and any problems encountered.Results:Of the 125 cases submitted, 121 (436 slides) were successfully scanned including 93 oncological and 28 donor-organ FS biopsies. Four cases were excluded because of failed digitalization due to scanning problems or sample preparation artifacts. Full agreement between glass and digital-slide diagnosis was obtained in 90 of 93 (97%, κ = 0.96) oncology and in 24 of 28 (86%, κ = 0.91) transplant cases. There were two major and one minor discrepancy for cancer cases (sensitivity 100%, specificity 96%) and two major and two minor disagreements for transplant cases (sensitivity 96%, specificity 75%). Average scan and viewing/reporting time were 12 and 3 min for cancer cases, compared to 18 and 5 min for transplant cases. A high diagnostic comfort level among pathologists emerged from the survey.Conclusions:These data demonstrate that the “Navigo” digital WSI system can reliably support an IO FS service involving complicated cancer and transplant cases.
Guidelines for donor selection have changed to expand the donor pool, considering potential donors affected by a neoplasm. Aim of this retrospective study is to look at the use of organs from donors with a current or history of neoplasm within the Italian Transplant Network. Data, collected and validated by Italian National Health Institute for the time interval 2006-2015, have been reviewed retrospectively by mean of multivariable pivot tables. Donors with neoplasia represented about 5% of all donors, resulting in about 4% of all transplants. Donors presented a benign neoplasm in 29.08% of cases, a malignancy with variable risk of transmission in 69.75% while in 1.34% the nature of neoplasm could not be assessed. Considering all procedures, rate of transmission of a malignancy was 0.03% (10 cases) of all 29858 transplants of the time interval. Notably, cases of transmission were not from donors of this pool, but from donors that, according to our protocols, had no elements of suspect at time of donation. As recipient safety is always the priority and as guidelines have set exclusion criteria for donors with some specific types of malignancy, these results show that use of this type of donors is safe and improve organ pool. Furthermore represent basis for improvement and standardization of donor assessment protocols suggesting that efforts in data collection systems, to produce complete and homogeneous data, are mandatory.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.