In this article, the efficiency of the tuned liquid column damper (TLCD) in reducing structural vibration is analyzed. The analysis by numerical methods and by analytical methods is adopted in the search for the ideal parameters for the liquid column. The equivalent linear model is considered for the U-shaped liquid column equation of motion with damping resulting from an orifice. Thus, variation of TLCD parameters for different loads is investigated. Initially, for the numerical study in conjunction with the analytical formulation, a sinusoidal forcing is adopted. Subsequently, the action of an earthquake through the recorded ground accelerations is considered in the case study. Optimal TLCD parameters are presented via response map for reducing the structure's maximum permanent response to harmonic excitation and for reducing the structure's rms response to seismic excitation with wide frequency and various amplitude. The variation of the TLCD parameters presented by the response map is directly related to the force acting on the structure. However, it is verified that regardless of the acting force, there is an ideal frequency range to tune the TLCD where the greatest reductions in the primary system response are found. It appears that reducing the aspect ratio of the liquid column makes this range narrower, making the damper more sensitive to parameter variations, as well as its performance. It is also observed that the increase in the attenuator mass ratio combined with the correct tuning and damping ratios present greater reductions in structural vibration. Also, the frequency ratio is reduced with the increase of the mass ratio, while the damping rate of the liquid column increases. From the ideal liquid column parameters determined by the parametric analysis, structural response reductions of approximately 60% were achieved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.