Water bridges formed through capillary condensation at nanoscale contacts first stretch and then break during contact rupture. Atomic force microscopy (AFM) pull-off experiments performed in air with hydrophilic tips and samples show that stretched nanoscopic water bridges are in mechanical equilibrium with the external pull-off force acting at the contact but not in thermodynamic equilibrium with the water vapor in air. The experimental findings are explained by a theoretical model that considers constant water volume and decrease of water meniscus curvature during meniscus stretching. The model predicts that the water bridge breakup distance will be roughly equal to the cubic root of the water bridge volume. A thermodynamic instability was noticed for large water bridges formed at the contact of a blunt AFM tip (curvature radius of 400 nm) with a flat sample. In this case, experiments showed rise and stabilization of the volume of the water at the contact in about 1 s. For sharp AFM tips (curvature radius below 50 nm), the experiments indicated that formation of stable water bridges occurs in a much shorter time (below 5 ms).
The inactivation of bacteria and biomolecules using plasma discharges were investigated within the European project BIODECON. The goal of the project was to identify and isolate inactivation mechanisms by combining dedicated beam experiments with especially designed plasma reactors. The plasma reactors are based on a fully computer-controlled, low-pressure inductively-coupled plasma (ICP). Four of these reactors were built and distributed among the consortium, thereby ensuring comparability of the results between the teams. Based on this combined effort, the role of UV light, of chemical sputtering (i.e. the combined impact of neutrals and ions), and of thermal effects on bacteria such as Bacillus atrophaeus, Aspergillus niger, as well as on biomolecules such as LPS, Lipid A, BSA and prions have been evaluated. The particle fluxes emerging from the plasmas are quantified by using mass spectrometry, Langmuir probe measurements, retarding field measurements and optical emission spectroscopy. The effects of the plasma on the biological systems are evaluated using atomic force microscopy, ellipsometry, electrophoresis, specially-designed western blot tests, and animal models. A quantitative analysis of the plasma discharges and the thorough study of their effect on biological systems led to the identification of the different mechanisms operating during the decontamination process. Our results confirm the role of UV in the 200-250 nm range for the inactivation of microorganisms and a large variability of results observed between different strains of the same species. Moreover, we also demonstrate the role of chemical sputtering corresponding to the synergism between ion bombardment of a surface with the simultaneous reaction of active species such as O, O 2 or H. Finally, we show that plasma processes can be efficient against different micro-organisms, bacteria and fungi, pyrogens, model proteins and prions. The effect of matrices is described, and consequences for any future industrial implementation are discussed.
Atomic force microscopy (AFM) indentation has become an important technique for quantifying the mechanical properties of live cells at nanoscale. However, determination of cell elasticity modulus from the force-displacement curves measured in the AFM indentations is not a trivial task. The present work shows that these force-displacement curves are affected by indenter-cell adhesion force, while the use of an appropriate indentation model may provide information on the cell elasticity and the work of adhesion of the cell membrane to the surface of the AFM probes. A recently proposed indentation model (Sirghi, Rossi in Appl Phys Lett 89:243118, 2006), which accounts for the effect of the adhesion force in nanoscale indentation, is applied to the AFM indentation experiments performed on live cells with pyramidal indenters. The model considers that the indentation force equilibrates the elastic force of the cell cytoskeleton and the adhesion force of the cell membrane. It is assumed that the indenter-cell contact area and the adhesion force decrease continuously during the unloading part of the indentation (peeling model). Force-displacement curves measured in indentation experiments performed with silicon nitride AFM probes with pyramidal tips on live cells (mouse fibroblast Balb/c3T3 clone A31-1-1) in physiological medium at 37 degrees C agree well with the theoretical prediction and are used to determine the cell elasticity modulus and indenter-cell work of adhesion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.