Background: It is not clear whether the mechanical strength of adjustable-loop suspension devices (ALDs) in anterior cruciate ligament (ACL) reconstruction is device dependent and if these constructs are different from those of an interference screw. Purpose: To compare the biomechanical differences of 2 types of ALDs versus an interference screw. Study Design: Controlled laboratory study. Methods: ACL reconstruction was performed on porcine femurs and bovine extensor tendons with 3 types of fixation devices: interference screw, UltraButton (UB) ALD, and TightRope (TR) ALD (n = 10 for each). In addition to specimen testing, isolated testing of the 2 ALDs was performed. The loading protocol consisted of 3 stages: preload (static 150 N load for 5 minutes), cyclic load (50-250 N at 1 Hz for 1000 cycles), and load to failure (crosshead speed 50 mm/min). Displacement at different cycles, ultimate failure load, yield load, stiffness, and failure mode were recorded. Results: In specimen testing, displacement of the ALDs at the 1000th cycle was similar (3.42 ± 1.34 mm for TR and 3.39 ± 0.92 mm for UB), but both were significantly lower than that of the interference screw (7.54 ± 3.18 mm) ( P < .001 for both). The yield load of the UB (547 ± 173 N) was higher than that of the TR (420 ± 72 N) ( P = .033) or the interference screw (386 ± 51 N; P = .013), with no significant difference between the latter 2. In isolated device testing, the ultimate failure load of the TR (862 ± 64 N) was significantly lower than that of the UB (1879 ± 126 N) ( P < .001). Conclusion: Both ALDs showed significantly less displacement in cyclic loading at ultimate failure than the interference screw. The yield load of the UB was significantly higher than that of the other 2. The ultimate failure occurred at a significantly higher load for UB than it did for TR in isolated device testing. Clinical Relevance: Both UB and TR provided stronger fixation than an interference screw. Although difficult to assess, intrinsic differences in the mechanical properties of these ALDs may affect clinical outcomes.
Little attention has been paid to knee muscle strength after ACL rupture and its effect on prognostic outcomes and treatment decisions. We studied hamstrings (H) and quadriceps (Q) strength correlation with a patient-reported outcome measures score (International Knee Documentation Committee, IKDC), anterior tibial translation (ATT), and time post-injury in 194 anterior cruciate ligament deficient patients (ACLD) who required surgery after a failed rehabilitation program (non-copers). The correlation between knee muscle strength and ATT was also studied in 53 non-injured controls. ACLD patients showed decreased knee muscle strength of both the injured and non-injured limbs. The median (interquartile range) values of the H/Q ratio were 0.61 (0.52–0.81) for patients’ injured side and 0.65 (0.57–0.8) for the non-injured side (p = 0.010). The median H/Q ratio for the controls was 0.52 (0.45–0.66) on both knees (p < 0.001, compared with the non-injured side of patients). The H/Q, ATT, and time post-injury were not significantly correlated with the IKDC score. ATT was significantly correlated with the H/Q of the injured and non-injured knees of patients, but not in the knees of the controls. Quadriceps strength and H/Q ratio were significantly correlated with ATT for both limbs of the patients. IKDC score correlated significantly with the quadriceps and hamstrings strengths of the injured limb but not with the H/Q ratio, ATT or time passed after injury.
The surgical correction of a hallux valgus (HV) deformity improves radiological parameters and clinical outcomes. However, it is not known how these improvements are related between themselves. In this retrospective study, 73 women were assessed preoperatively and 60 months after HV surgical correction. Several radiological parameters were measured: the hallux valgus angle (HVA), I–II intermetatarsal angle (IMA) and sesamoid position. The functional outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) Hallux Metatarsophalangeal-Interphalangeal (HMI) scale, and patient-reported outcomes (PROMs) were recorded with the Manchester–Oxford Foot Questionnaire (MOXFQ). A pre–post-surgery comparison of radiological and clinical values was performed, the correlation among them was studied and the differences pre–post-surgery in the radiological measurements compared with those for the clinical outcomes were studied. The results show that all the radiological parameters, functional outcomes and PROMs improved significantly from their pre-operative values to the follow-up values. Multivariate regression analysis showed a significant relationship (p < 0.001) between the differential pre–post-surgery AOFAS scoring only with two sesamoid position differential pre–post-surgery measures: position of medial sesamoid (PMS) and translation of the first metatarsal head (TMH). However, no significant association was observed between the pre–post-surgery radiological differences and the pre–post-surgery MOXFQ scoring.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.