The surface of Ni-based alloy 690 was treated using a sub-microsecond pulsed laser in order to reduce the amount of nickel released when the surface is exposed to the primary cooling system of pressurized water nuclear reactors. A 2D array of laser treatment parameter sets was investigated. The results on sample surfaces was characterized using interferometric microscopy, Scanning Electron Microscopy (SEM), Glow Discharge Optical Emission Spectrometry (GDOES) and X-ray Photoelectron Spectrometry (XPS). The treatment leading to a continuous and defect-free chromine surface having the minimum nickel content over about the first two nanometers and no subsurface chromium depletion was selected for the nickel release test. This selection criterion proved to be very efficient as the total amount of nickel released in a standard qualification test using a simulated primary coolant was reduced, compared to a non-treated surface, by a factor of 7 during the heating phase and by a factor of 3.7 on average over the whole month-long test.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.