Technetium (99mTc) labelled, polyclonal human immunoglobulin (HIG) is a new agent that detects focal infection and inflammation. This new agent was compared in 40 patients with the accepted standard, namely 111In-oxine-labelled leucocytes. This comparison resulted in a sensitivity of 94% and a specificity of 96% for 99mTc-HIG when 111In-oxine leucocytes were defined as giving the true result. The new agent was shown to localize both sepsis and active inflammatory bowel disease (IBD). There was 100% concordance in the 16 patients with IBD who were imaged with both 99mTc-HIG and 111In-oxine leucocytes. Discordant results were obtained in one case of suspected osteomyelitis, which was false-positive on the 99mTc-HIG scan, and one case of pyrexia of unknown origin when the 99mTc-HIG was false-negative and the 111In-oxine leucocyte scan demonstrated accumulation of tracer in the caecum at 24 h post-injection. Normal distribution for 99mTc-HIG demonstrated activity in the kidneys and bladder and that 50% of the tracer is cleared through the kidneys during the first 24 h post-injection. There were no major or minor side-effects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.