The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Executive Services and Communications Directorate (0704-0188). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.
Multi-phase soft-switching high-frequency isolated DC-DC converter is proposed for power conversion in modular stacked HVDC power transmission and distribution system. Input-series output-parallel connection of current-fed full-bridge DC-DC converter modules is proposed to increase voltage blocking capability at the input and decrease current ripple at the output. Basic power electronic building block is zero-current switching (ZCS) fullbridge phase-shift PWM DC-DC converter. Phase shift between switches in each leg of the converter is adjusted to control power flow while phase shift between gate signals of individual phases is selected according to the number of phases in order to minimize ripple of the output voltage. Converter analysis is carried out to develop a simple equivalent boost converter model of the three-phase soft-switching converter suitable for system-level analysis and simulation. Strategies are developed to ensure fast detection of faults and continued operation of the converter in the case of fault in one phase module. To verify the proposed system design and analysis, experimental results on scaled-down laboratory prototype are presented for a three-phase ZCS DC-DC converter. Index Terms Isolated DC-DC converter, zero-current-switching, subsea power distribution v An early version of this work has been presented at IEEE IECON 2013. Mohammadpour, A.; Parsa, L.; Todorovic, M.H.; Rixin Lai; Datta, R., "Interleaved multi-phase ZCS isolated DC-DC converter for sub-sea power distribution
Unintentional islanding protection of distributed generation is a key function for standards compliance. For those distributed generations that use an inverter as grid interface, the function can be implemented as part of the inverter control. Existing anti-islanding schemes used in inverters have power quality and non-detection zone issues. This paper proposes a new family of schemes that have negligible power quality degradation and no non-detection zone. Design guidelines based on frequency-domain analysis is also provided. Finally, both simulation and experimental results validate the proposed schemes.
1.0-7803-8399-0/04/$20.00 8 2 W IEEE.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.