The true role of entanglement in two-photon virtual-state spectroscopy (Saleh et al 1998 Phys. Rev. Lett. 80 3483), a two-photon absorption spectroscopic technique that can retrieve information about the energy level structure of an atom or a molecule, is controversial. The consideration of closely related techniques, such as multidimensional pump-probe spectroscopy (Roslyak et al 2009 Phys. Rev. A 79, 063409), suggests that spectroscopic information might also be retrieved by using uncorrelated pairs of photons. Here we show that this is not the case. In the two-photon absorption process, the ability to obtain information about the energy level structure of a medium depends on the spectral shape of existing temporal (frequency) correlations between the absorbed photons. In fact, it is a combination of both the presence of frequency correlations (entanglement) and their specific spectral shape that makes the
We demonstrate a different scheme to perform optical sectioning of a sample based on the concept of induced coherence [Zou et al., Phys. Rev. Lett. 67, 318 (1991)]. This can be viewed as a different type of optical coherence tomography scheme where the varying reflectivity of the sample along the direction of propagation of an optical beam translates into changes of the degree of first-order coherence between two beams. As a practical advantage the scheme allows probing the sample with one wavelength and measuring photons with another wavelength. In a bio-imaging scenario, this would result in a deeper penetration into the sample because of probing with longer wavelengths, while still using the optimum wavelength for detection. The scheme proposed here could achieve submicron axial resolution by making use of nonlinear parametric sources with broad spectral bandwidth emission.
We demonstrate experimentally a scheme to measure small temporal delays, much smaller than the pulse width, between optical pulses. Specifically, we observe an interference effect, based on the concepts of quantum weak measurements and weak value amplification, through which a sub-pulse-width temporal delay between two femtosecond pulses induces a measurable shift of the central frequency of the pulse. The amount of frequency shift, and the accompanying losses of the measurement, can be tailored by postselecting different states of polarization. Our scheme requires only spectrum measurements and linear optics elements, hence greatly facilitating its implementation. Thus it appears to be a promising technique for measuring small and rapidly varying temporal delays.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.