Objectives To validate an experimental non-animal model for training of vasectomy reversal.Materials and Methods The model consisted of two artificial vas deferens, made with silicon tubes, covered by a white resin, measuring 10 cm (length) and internal and external diameters of 0.5 and 1.5 mm, respectively. The holder of the ducts is made by a small box developed with polylactic acid, using a 3D print. The objective of the invention is to simulate the surgical field of vasovasostomy, when the vas deferens are isolated from other cord structures. For validation, it was verified the acquisition of microsurgical skills during its use, in a capacitation course with 5 urology residents from a Hospital of the region. Along the training sessions, it was analyzed the time (speed) of microsurgical sutures, and quantification of the performance using a checklist. Collected data were analyzed using de BioEstat®5.4 software.Results Medium time for the completion of microsurgical sutures improved considerably during the course, and reached a plateau after the third day of training (p=0.0365). In relation to the checklist, it was verified that during capacitation, there was significant improvement of the scores of each participant, that reached a plateau after the fourth day of training with the model (p=0.0035).Conclusion The developed model was able to allow the students that attended the course to gain skills in microsurgery, being considered appropriate for training vasectomy reversal.
Objectives: To evaluate the prevalence, distribution and association of HPV with histological pattern of worse prognosis of penile cancer, in order to evaluate its predictive value of inguinal metastasis, as well as evaluation of other previous reported prognostic factors. Material and Methods: Tumor samples of 82 patients with penile carcinoma were tested in order to establish the prevalence and distribution of genotypic HPV using PCR. HPV status was correlated to histopathological factors and the presence of inguinal mestastasis. The influence of several histological characteristics was also correlated to inguinal disease-free survival. Results: Follow-up varied from 1 to 71 months (median 22 months). HPV DNA was identified in 60.9% of sample, with higher prevalence of types 11 and 6 (64% and 32%, respectively). There was no significant correlation of the histological characteristics of worse prognosis of penile cancer with HPV status. Inguinal disease-free survival in 5 years did also not show HPV status influence (p = 0.45). The only independent pathologic factors of inguinal metastasis were: stage T ≥ T1b-T4 (p = 0.02), lymphovascular invasion (p = 0.04) and infiltrative invasion (p = 0.03). Conclusions: HPV status and distribution had shown no correlation with worse prognosis of histological aspects, or predictive value for lymphatic metastasis in penile carcinoma.
Objetivo: O estudo idealizou o desenvolvimento e validação de um simulador confeccionado em impressora 3D para a capacitação em ureterolitotripsia flexível com laser. Métodos: O simulador foi confeccionado com ácido polilático e é constituído por duas partes, que se fecham de maneira hermética. O seu interior imita um sistema urinário, constituído de ureter proximal, pelve e cálices renais, permitindo o treinamento de navegação com endoscópio, a litotripsia com laser, bem como a remoção dos fragmentos de cálculos. Para validação, o simulador foi avaliado por 21 juízes especialistas, que tiveram acesso à tecnologia individualmente e puderam verificar suas principais características e funcionalidades. A avaliação foi documentada através do preenchimento de um questionário, contendo 22 afirmativas em escala Likert, dividias em três domínios: (1) OBJETIVOS, (2) ESTRUTURA e APRESENTAÇÃO e (3) RELEVÂNCIA. Resultados: Os 3 domínios obtiveram a aprovação de, respectivamente, 98,6%,98,3% e 99,3%. A consistência interna do questionário foi verificada através do teste Alfa de Cronbach que alcançou altos valores, tanto nos domínios (0.829, 0,87 e 0.9963), quanto na avaliação geral (0.92). Conclusão: O simulador desenvolvido permite o treinamento de cirurgia de ureterolitotripsia flexível com laser, podendo ser considerado uma ferramenta auxiliar no ensino-aprendizado em urologia.
_______________________________________________________________________________________Introduction: Tissue transfer has been used in urethral reconstruction for decades, and several grafts have been described (1, 2). The ideal graft would have optimal tissue characteristics and lead to minimal morbidity at the donor site. Urethroplasty using bladder mucosa was first described by Memmelaar in 1947 (3). The main limitation in using bladder mucosal grafts has been the invasiveness of open harvesting (4). We describe an endoscopic technique using Holmium:YAG laser to harvest bladder mucosal graft for substitution urethroplasty. Methodology: A 33-year-old male with no history of urethral instrumentation, trauma, or infection presented with obstructive lower urinary tract symptoms. On retrograde urethrogram a 6cm bulbar urethral stricture was identified. Several options were discussed, and the patient opted for a one-sided onlay dorsal urethroplasty (5) using a bladder mucosal graft. Equipment used to harvest the graft included an 18.5Fr continuous flow laser endoscope with a Kuntz working element (RZ) and a 60W Holmium Laser (Quanta) with 550μm laser fiber. The procedure was started by making a perineal incision, urethral mobilization and incision of the stricture segment. The laser endoscope was then introduced via the perineum. Settings of 0.5J, 30 Hz, and long pulse were used and a 7 x 2.5cm graft was harvested from the posterior bladder wall. Hemostasis of the harvest site was performed. The bladder mucosal graft was thinned in similar fashion to a buccal mucosal graft and sutured as per previously described techniques. Conclusion: Endoscopic Holmium Laser harvesting of bladder mucosal graft is feasible and may allow this graft to become an alternative to buccal mucosa. Further studies are required to define its role in urethral reconstruction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.