Antibiotics can be easily bought in the great majority of the pharmacies in our town without a medical prescription and a clear indication. Fever temperature did not modify the attendant's indication of the drug.
Mechanical ventilation asynchrony was influenced by effort, respiratory mechanics, ventilator type, and ventilation mode. In PSV mode, delayed cycling was associated with shorter effort in obstructive respiratory mechanics profiles, whereas premature cycling was more common with longer effort and a restrictive profile. PAV+ prevented premature cycling but not delayed cycling, especially in obstructive respiratory mechanics profiles, and it was associated with a lower V.
Background: The digital Auto-Trak™ system is a technology capable of automatically adjusting the triggering and cycling mechanisms during pressure support ventilation (PSV). Objective: To compare Auto-Trak with conventional settings in terms of patient-ventilator synchrony and discomfort. Methods: Twelve healthy volunteers underwent PSV via the mouth by breathing through an endotracheal tube. In the conventional setting, a pressure support of 8 cm H2O with flow cycling (25% peak inspiratory flow) and a sensitivity of 1 cm H2O was adjusted. In Auto-Trak the triggering and cycling were automatically set. Discomfort, effort of breathing, and the asynchrony index (AI) were assessed. In a complementary bench study, the inspiratory and expiratory time delays were quantified for both settings in three mechanical models: ‘normal', obstructive (COPD), and restrictive (ARDS), using the ASL 5000 simulator. Results: In the volunteer study the AI and the discomfort scores did not differ statistically between the two settings. In the bench investigation the use of Auto-Trak was associated with a greater triggering delay in the COPD model and earlier expiratory cycling in the ARDS model but with no asynchronic events. Conclusions: Use of the Auto-Trak system during PSV showed similar results in comparison to the conventional adjustments with respect to patient-ventilator synchrony and discomfort in simulated conditions of invasive mechanical ventilation.
Objective: To compare the incidence and intensity of acute adverse effects and the variation in the temperature of facial skin by thermography after the use of noninvasive ventilation (NIV). Methods: We included 20 healthy volunteers receiving NIV via oronasal mask for 1 h. The volunteers were randomly divided into two groups according to the ventilatory mode: bilevel positive airway pressure (BiPAP) or continuous positive airway pressure (CPAP). Facial thermography was performed in order to determine the temperature of the face where it was in contact with the mask and of the nasal dorsum at various time points. After removal of the mask, the volunteers completed a questionnaire about adverse effects of NIV. Results: The incidence and intensity of acute adverse effects were higher in the individuals receiving BiPAP than in those receiving CPAP (16.1% vs. 5.6%). Thermographic analysis showed a significant cooling of the facial skin in the two regions of interest immediately after removal of the mask. The more intense acute adverse effects occurred predominantly among the participants in whom the decrease in the mean temperature of the nasal dorsum was lower (14.4% vs. 7.2%). The thermographic visual analysis of the zones of cooling and heating on the face identified areas of hypoperfusion or reactive hyperemia. Conclusions: The use of BiPAP mode was associated with a higher incidence and intensity of NIV-related acute adverse effects. There was an association between acute adverse effects and less cooling of the nasal dorsum immediately after removal of the mask. Cutaneous thermography can be an additional tool to detect adverse effects that the use of NIV has on facial skin.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.