The aim of this work is a proof of concept, that medical Internet of Things (IoT) sterilization surveillance sensors can be powered by using the heat during a steam sterilization procedure. Hereby, the focus was on the use of thermo-electrical generators (TEG) to generate enough power for an ultra-low-power sensor application. Power generation requirement of the sensor was 1.6 mW over the single sterilization cycle. The thermal gradient across the TEG has been achieved using a highly efficient aerogel-foam-based thermal insulation, shielding a heat storage unit (HSU), connected to one side of the TEG. The evaluation of the developed system was carried out with thermal and electrical simulations based on the parameters extracted from the TEG manufacturer’s datasheet. The developed model has been validated with a real prototype using the thermal step response method. It was important for the authors to focus on rapid-prototyping and using off-the-shelf devices and materials. Based on comparison with the physical prototype, the SPICE model was adjusted. With a thermal gradient of 12 °C, the simulated model generated over 2 mW of power. The results show that a significant power generation with this system is possible and usable for sensor applications in medial IoT.
Surgical procedures involve major risks, as pathogens can enter the body unhindered. To prevent this, most surgical instruments and implants are sterilized. However, ensuring that this process is carried out safely and according to the normative requirements is not a trivial task. This study aims to develop a sensor system that can automatically detect successful steam sterilization on the basis of the measured temperature profiles. This can be achieved only when the relationship between the temperature on the surface of the tool and the temperature at the measurement point inside the tool is known. To find this relationship, the thermodynamic model of the system has been developed. Simulated results of thermal simulations were compared with the acquired temperature profiles to verify the correctness of the model. Simulated temperature profiles are in accordance with the measured temperature profiles, thus the developed model can be used in the process of further development of the system as well as for the development of algorithms for automated evaluation of the sterilization process. Although the developed sensor system proved that the detection of sterilization cycles can be automated, further studies that address the possibility of optimization of the system in terms of geometrical dimensions, used materials, and processing algorithms will be of significant importance for the potential commercialization of the presented solution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.