In laparoscopy, specimens have to be removed from the abdominal cavity. If the trocar opening or the vaginal outlet is insufficient to pass the specimen, the specimen needs to be reduced. The power morcellator is an instrument with a fast rotating cylindrical knife which aims to divide the tissue into smaller pieces or fragments. The Food and Drug Administration (FDA) issued a press release in April 2014 that discouraged the use of these power morcellators. This article has the objective to review the literature related to complications by power morcellation of uterine fibroids in laparoscopy and offer recommendations to laparoscopic surgeons in gynaecology. This project was initiated by the executive board of the European Society of Gynaecological Endoscopy. A steering committee on fibroid morcellation was installed and experienced ESGE members requested to chair an action group to address distinct clinical questions. Clinical questions were formulated with regards to the sarcoma risk in presumed uterine fibroids, diagnosis of sarcoma, complications of morcellation and future research. A literature review on the different subjects was conducted, systematic if appropriate and feasible. It was concluded that the true prevalence of uterine sarcoma in presumed fibroids is not known given the wide range of prevalences (0.45–0.014 %) from meta-analyses mainly based on retrospective trials. Age and certain imaging characteristics such as ‘lacunes’ suggesting necrosis and increased central vascularisation of the tumour are associated with a higher risk of uterine sarcoma, although the risks remain low. There is not enough evidence to estimate this risk in individual patients. Complications of morcellation are rare. Reported are direct morcellation injuries to vessels and bowel, the development of so-called parasitic fibroids requiring reintervention and the spread of sarcoma cells in the abdominal cavity, which may possibly or even likely upstaging the disease. Momentarily in-bag morcellation is investigated as it may possibly prevent morcellation complications. Because of lack of evidence, this literature review cannot give strong recommendations but offers only options which are condensed in a flow chart. Prospective data collection may clarify the issue on sarcoma risk in presumed fibroids and technology to extract tissue laparoscopically from the abdominal cavity should be perfected.
Despite the substantial heterogeneity of the study population, this meta-analysis provides valuable information on relative treatment efficacy of various uterine-sparing interventions for fibroids, which is relevant when counseling patients in daily practice. Furthermore, this study demonstrates that long-term data, particularly for the newest uterine-sparing interventions, are urgently needed.
Purpose This review aims to objectively assess the efficacy and safety of uterine manipulators as reported in scientific literature. Furthermore, it evaluates as to which manipulator best suits which surgical procedure. Methods PubMed, Embase, Web of Science, COCHRANE, CINAHL, Academic Search Premier, Science Direct and the MAUDE database were searched. Technical information was retrieved from the manufacturers. Results 25 articles covering 10 uterine manipulators were found. Studies regarding implementation and use of manipulators are scarce; only two surveys were found comparing different manipulators. Moreover, clinical evidence proving the efficacy of manipulators with respect to prevention of complications, inherent to laparoscopic surgery, does not exist. Conclusion The use of uterine manipulators is well established and it is clear that uterine manipulators offer the easiest way to handle the uterus during surgery. However, detailed information regarding efficacy and safety is scarce. Clinical evidence substantiating the assumed mechanism of prevention of ureter injuries was not found. Our review did not find the optimal manipulator. Some are more versatile than others and not all instruments are appropriate for all types of surgery. Therefore, gynecologists should choose the manipulator that best suits the type of surgery that is performed.
From the available literature, we found a 74% prevalence of physical complaints among laparoscopic surgeons. However, the low response rates and the high inconsistency across studies leave some uncertainty, suggesting an actual prevalence of between 22% and 74%. Fatigue and MSDs impact psychomotor performance; therefore, these results warrant further investigation. Continuous changes are enacted to increase patient safety and surgical care quality, and should also include efforts to improve surgeons' well-being.
Even during conventional myomectomy, tissue spillage occurs during resection of leiomyoma(s).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.