ObjectiveTo assess the long-term incidence of venous complications, including portal vein and hepatic vein stenoses, in both whole cadaveric and reduced-size cadaveric and living related liver transplants in a pediatric population, and to assess the therapeutic modalities in the treatment of these lesions. Summary Background DataA shortage in appropriate-sized liver grafts for pediatric patients led to the use of segmental liver grafts, which became the predominant graft used in 325 of 600 (54%) transplants at the authors' institution. To assess the long-term impact of this strategy, the authors examined the incidence of late (Ͼ90 days) venous complications and the efficacy of all therapeutic interventions. MethodsSix hundred pediatric liver transplants were performed in 325 patients, with reduced-size or split (RSS; n ϭ 207), living related (LRD; n ϭ 118), or full-size cadaveric grafts (FS; n ϭ 275) from 1988 to 2000. All transplants identified with late portal vein or vena caval stenoses or thromboses from a cohort of 524 grafts with survival greater than 90 days were reviewed for demographics, symptoms, therapeutic intervention, recurrence, morbidity, and mortality. ResultsFifty lesions were identified in 49 patients (38 portal vein and 12 hepatic vein-cava stenoses). Sex distribution was similar between portal vein and hepatic vein to cava, as was the mean patient age. Portal vein stenoses occurred in 32 LRD, 3 RSS, and 3 FS, while hepatic vein-cava stenoses occurred in 2 LRD, 8 RSS, and 2 FS. In the 38 portal vein stenoses, 9 had prior perioperative portal vein and/or 5 hepatic artery thrombectomies. Portal vein stenoses were identified after bleeding (17/38), ascites (6/38), increased liver function tests (6/38), splenomegaly (5/38), or screening ultrasound (4/38). Portal vein stenosis was associated most often with cryopreserved vein for portal conduits. Excluding conduits, the incidence of late portal vein complications was reduced to 1%. Lesions became symptomatic at a mean of 50.8 Ϯ 184.2 months posttransplant. All patients underwent venous angioplasty with a 66% (25/38) success rate, while 7 of 25 required further angioplasty and stenting. In the 13 unsuccessful angioplasties, 8 required surgical shunts for complete portal vein thrombosis. Recurrence occurred in 9 patients: all were amenable to stenting. Nine patients (24%) eventually died of sepsis (4) and surgical deaths at shunt or retransplant (5). Hepatic vein-cava stenoses occurred after a mean of 37.2 Ϯ 35.2 months, presenting with ascites (n ϭ 10), increased liver function tests (n ϭ 2), and splenomegaly (n ϭ 2). All patients were diagnosed by venogram and managed by balloon dilatation alone (n ϭ 6) or stented (n ϭ 4), with an 80% (10/12) success, with two late recurrences amenable to repeat angioplasty or stenting. Long-term survival was 80% at 1 year. ConclusionsThe use of segmental grafts without venous conduits is not associated with a significant rate of long-term venous complication. When late venous complications do occur, venous angiop...
Percutaneous treatment of portal venous stenoses is effective and long lasting in children with reduced-size hepatic transplants. In patients with elastic or recurrent lesions, portal venous stents have excellent long-term primary patency despite continued patient growth. Successful, percutaneous transhepatic venoplasty eliminates the need for surgical revision, portacaval shunting, or repeat transplantation.
ObjectiveA review of 100 living-liver donors was performed to evaluate the perisurgical complications of the procedure and thus to help quantify the risks to the donor. Summary Background DataDespite the advantages of living-donor liver transplantation (LDLT), the procedure has received criticism for the risk it imposes on healthy persons. A paucity of data exists regarding the complications and relative safety of the procedure. MethodsOne hundred LDLTs performed between November 1989 and November 1996 were reviewed. Donor data were obtained by chart review, anesthesia records, and the computerized hospital data base. Patient variables were compared by Fisher's exact test and the Student's t test. ResultsThere were 57 women and 43 men with a median age of 29. Donors were divided into two groups: group A (first 50 donors), and group B (last 50 donors). There were 91 left lateral segments and 9 left lobes. There were no deaths. Fourteen major complications occurred in 13 patients; 9 occurred in group A and 5 in group B. Biliary complications consisted of five bile duct injuries (group A = 4, group B = 1) and two cut edge bile leaks. Complications were more common in left lobe resections (55%) than in left lateral segment grafts (10%). Minor complications occurred in 20% of patients. A significant reduction in overall complications (major and minor) was observed between the groups (group A, n = 24 [45%] vs. group B, n = 10 [20%]). In addition, surgical time and hospital stay were both significantly reduced. ConclusionsAlthough the procedure is safe, many LDLT donors have a perisurgical complication. Surgical experience and technical modifications have resulted in a significant reduction in these complications, however. To minimize the risks for these healthy donors, LDLT should be performed at institutions with extensive experience.
The living-donor liver transplant recipient operation has undergone significant technical changes since its introduction in 1989. These changes have decreased the vascular complications associated with this type of graft. Avoiding the use of vascular conduits and performing microvascular hepatic artery anastomoses are the critical steps in improving graft survival.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.