Wetting of a pollution layer by mist or light rain is inhibited, in the case of silicone rubber (SiR) insulators, by the migration of hydrophobic polymeric chains from the insulator to the layer surface. However, recent laboratory fog-chamber tests have shown that a salt/kaolin layer applied to the surface of an 11kV SiR insulator can reduce the specific creepage distance (SCD) at flashover to as low as 16mm/kV. Even for larger values of SCD, potentially damaging partial arcs can arise along the insulator surface. It has been shown that some mitigation of partial-arc activity and an increase of flashover voltage can be achieved by appropriate texturing of the SiR insulator housing. The present paper describes additional infrared (IR) recording which accompanied these previous tests. Although a reduction of the flashover voltage in polluted environments is generally surmised to be the result of the formation of dry bands in a conducting moistened surface layer, no direct observations of dry bands appear to have been previously demonstrated in the laboratory. Such observations are described here, where details of dry-band location and growth are revealed by IR recording. Dry bands are shown by close-up visual photography to be invariably bridged by small streamer/spark discharges which maintain current continuity in the pollution layer. Local surface heating by these discharges are the probable cause of the delayed rewetting of the bands. Partial-arc channels that may result in flashover develop from and across the dry-band streamers. It has become clear that clean-fog testing with infrared recording and leakage current measurements provide new possibilities for the modeling of dry band discharges and improvement of insulator design.
This paper investigates the possible options for achieving a substantial reduction in a substation footprint using air-insulated switchgear as a more environmentally-friendly alternative to gas-insulated substations that use SF6 gas. Adopting a new approach to surge arrester location and numbers, International Electrotechnical Commission (IEC) minimum clearances can be successfully selected instead of the maximum clearances as currently adopted by many utilities, as is the case in the UK. In addition, innovative alternative compact busbar arrangements using vertical and delta configurations have been proposed by the authors. A further opportunity for compaction is offered by the application of compact and integrated technology offered from several manufacturers. The full overvoltage control within the entire substation under any surge condition is a key aspect of the feasibility of this type of substation. This work demonstrates that the new design option can be an attractive alternative for future substation configuration with minimum footprint.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.