Measurements made on routine A-P radiographs can predict strength/quality of the proximal humerus, as shown in terms of two easy-to-measure parameters: Cortical index (CI) and mean-combined cortical thickness (MCCT). Because of high variability inherent when using established methods to measure these parameters, we describe a new orientation system. Using digitized radiographs of 33 adult proximal humeri, five observers measured anatomical reference locations in accordance with: (i) Tingart et al. (2003) method, (ii) Mather et al. (2013) method, and (iii) our new humeral head Circle-Fit method (CFM). The Tingart and Mather methods measure CI and MCCT with respect to upper and lower edges of 20 mm tall rectangles fit to a proximal diaphyseal location where endosteal (Tingart) or periosteal (Mather) cortical margins become parallel. But high intra- and inter-observer variability occurs when placing the rectangles because of uncertainty in identifying cortical parallelism. With the CFM an adjustable circle is fit to the humeral head articular surface, which reliably and easily establishes a proximal metaphyseal landmark (M1) at the surgical neck. Distal locations are then designated at successive 10 mm increments below M1, including a second metaphyseal landmark (M2) followed by diaphyseal (D) locations (D1, D2 ⋯D6). D1 corresponds most closely to the proximal edges of the rectangles used in the other methods. Results showed minimal inter-observer variations (mean error, 1.5 ± 1.1 mm) when the CFM is used to establish diaphyseal locations for making CI and MCCT measurements when compared to each of the other methods (mean error range, 10.7 ± 5.9 to 13.3 ± 6.7 mm) (p < 0.001). © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2313-2322, 2017.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.