This paper describes experiments carried out at the National Physical Laboratory using a hydrogen maser in comparison with a group of caesium standards which define the NPL time scale. A technique is developed for setting the maser and measuring its frequency with a reproducibility of 1 part in 10l2. Three storage bulbs of different size coated with Teflon FEP-120 and three m t h Fluon GP1 are used to verify the linear relationship between maser frequency and inverse bulb diameter. The frequency at infinite bulb size is found by extrapolation, the uncertainty in this process being reduced by the use of the two coating materials. In terms of the international time unit, the unperturbed hydrogen hyperfine transition frequency is found to be f~ = 1420405751.7662 ? 0.003 Hz.The effect of contaminating a normally coated bulb with unsintered coating material is investigated. The temperature coefficient of the wall shift for the two materials is investigated over the range 11 to 75" C and it is found that zero wall shift is obtained at 80" C for FEP-120 and a t 126 "C for GP1. The results provide experimental verification of the 2nd order Poppler shift within the limits of error of the measurements ( ? 1 part in Bulbs were measured a t intervals over a period of 2 years and there is no evidence of frequency changes exceeding i: 1 part in 1Ol2. The difficulty of tuning the maser by changing the atomic flux is discussed, and an alternative method is described. It is concluded that the best way of operating the maser as a standard is by continuously resetting the cavity by a servo. A large bulb has a temperature coefficient less than 5 parts in 1014/"C and the maser could form a definitive standard with only simple control of the room temperature.
The Balloon Intercomparison Campaign (BIC) was set up to intercompare remote sensing measurements of a number of compounds other than water vapor; however, water vapor has strong absorption features throughout the infrared and mm wave regions of the spectrum. Therefore many of the investigators involved in BIC have absorption or emission features due to water vapor in the data they obtained during the balloon flights made under the campaign.These features have been used by the investigators to determine the stratospheric water vapor profiles which are compared in this paper. The profiles allow comparison of a wide range of remote sensing techniques involving both emission and absorption in the mid-infrared and emission techniques in the far infrared.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.