Main Recommendations
1 ESGE suggests that high definition endoscopy, and dye or virtual chromoendoscopy, as well as add-on devices, can be used in average risk patients to increase the endoscopist’s adenoma detection rate. However, their routine use must be balanced against costs and practical considerations.Weak recommendation, high quality evidence.
2 ESGE recommends the routine use of high definition systems in individuals with Lynch syndrome.Strong recommendation, high quality evidence.
3 ESGE recommends the routine use, with targeted biopsies, of dye-based pancolonic chromoendoscopy or virtual chromoendoscopy for neoplasia surveillance in patients with long-standing colitis.Strong recommendation, moderate quality evidence.
4 ESGE suggests that virtual chromoendoscopy and dye-based chromoendoscopy can be used, under strictly controlled conditions, for real-time optical diagnosis of diminutive (≤ 5 mm) colorectal polyps and can replace histopathological diagnosis. The optical diagnosis has to be reported using validated scales, must be adequately photodocumented, and can be performed only by experienced endoscopists who are adequately trained, as defined in the ESGE curriculum, and audited.Weak recommendation, high quality evidence.
5 ESGE recommends the use of high definition white-light endoscopy in combination with (virtual) chromoendoscopy to predict the presence and depth of any submucosal invasion in nonpedunculated colorectal polyps prior to any treatment. Strong recommendation, moderate quality evidence.
6 ESGE recommends the use of virtual or dye-based chromoendoscopy in addition to white-light endoscopy for the detection of residual neoplasia at a piecemeal polypectomy scar site. Strong recommendation, moderate quality evidence.
7 ESGE suggests the possible incorporation of computer-aided diagnosis (detection and characterization of lesions) to colonoscopy, if acceptable and reproducible accuracy for colorectal neoplasia is demonstrated in high quality multicenter in vivo clinical studies. Possible significant risks with implementation, specifically endoscopist deskilling and over-reliance on artificial intelligence, unrepresentative training datasets, and hacking, need to be considered. Weak recommendation, low quality evidence.
BACKGROUND & AIMS: Serrated polyposis syndrome (SPS), characterized by multiple and/or large proximal serrated lesions, increases the risk of colorectal cancer. Serrated lesions often are missed during colonoscopy but panchromoendoscopy can increase their detection in an average-risk population. We performed a randomized controlled study to determine the efficacy of panchromoendoscopy in detection of polyps in patients with SPS. METHODS: Patients with SPS (n [ 86 patients) underwent tandem high-definition (HD) colonoscopies from February 2015 through July 2016 at 7 centers in Spain. Patients were assigned randomly to groups that received 2 HD white-light endoscopy examinations (HD-WLE group; n [ 43) or HD-WLE followed by 0.4% indigo carmine panchromoendoscopy (HD-CE group; n [ 43). For each procedure, polyps detected were described, removed, and analyzed by histology. The primary outcome was additional polyp detection rate, defined as the number of polyps detected during the second inspection divided by the total number of polyps detected during the first and the second examination. RESULTS: A total of 774 polyps were detected (362 in the HD-WLE group and 412 in the HD-CE group); 54.2% were hyperplastic, 13.8% were adenomas, and 10.9% were sessile serrated polyps. There was a significantly higher additional polyp detection rate in the HD-CE group (0.39; 95% CI, 0.35-0.44) than in the HD-WLE group (0.22; 95% CI, 0.18-0.27) (P < .001). A higher additional rate of serrated lesions proximal to the sigmoid colon were detected in the second inspection with HD-CE (0.40; 95% CI, 0.33-0.47) than with HD-WLE (0.24; 95% CI, 0.19-0.31) (P [ .001). Detection of adenomas and serrated lesions greater than 10 mm did not differ significantly between groups. In a multivariate logistic regression analysis, only use of HD-CE was associated independently with increased polyp detection throughout the colon. CONCLUSIONS: In a randomized controlled trial, we found that panchromoendoscopy increases detection of polyps (mostly of small serrated lesions) and should be considered the standard of care in patients with SPS. Studies are needed to determine the effects of this strategy on the incidence of advanced neoplasia during long-term follow-up evaluation. ClinicalTrials.gov no: NCT03476434.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.