The authors have developed a simplified and efficient protocol to measure doses delivered by an IMRT or VMAT plan using only the patient film, one calibration film, one unexposed film, and applying a single scan to acquire a digital image for calculation and analysis. The simplification and timesaving offer a potential practical solution for using radiochromic film for routine treatment plan quality assurance without sacrificing spatial resolution for convenience.
Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT∕VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.
Objective To review the performance of non-invasive prenatal testing (NIPT) by low-coverage whole-genome sequencing of maternal plasma DNA at a single center.
Methods
Objective To report secondary or additional findings arising from introduction of non-invasive prenatal testing (NIPT) for aneuploidy by whole genome sequencing as a clinical service.Methods Five cases with secondary findings were reviewed.
ResultsIn Case 1, NIPT revealed a large duplication in chromosome 18p, which was supported by arrayCGH of amniocyte DNA, with final karyotype showing mosaic tetrasomy 18p. In Case 2, a deletion in the proximal long arm of chromosome 18 of maternal origin was suspected and confirmed by arrayCGH of maternal white cell DNA. In Case 3, NIPT was negative for trisomies 21 and 18. In-depth analysis for deletions/duplications was requested when fetal structural anomalies were detected at routine scan. A deletion in the proximal long arm of chromosome 3 was found and confirmed by karyotyping. In Case 4, NIPT correctly predicted confined placental mosaicism with triple trisomy involving chromosomes X, 7 and 21. In Case 5, NIPT correctly detected a previously unknown maternal mosaicism for 45X.Conclusion Non-invasive prenatal testing is able to detect a wide range of fetal, placental and maternal chromosomal abnormalities. This has important implications on patient counseling when an abnormality is detected by NIPT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.