We designed this multicenter trial to evaluate the performance and safety of the Ambu laryngeal mask, a new disposable supraglottic airway device, in patients scheduled for elective surgery. One-hundred-eighteen nonparalyzed, anesthetized patients (ASA physical status I-II, age, 18-65 yr, body mass index, 18-30 kg/m(-2)) receiving total IV anesthesia were included in this study. After device insertion, fiberoptic position and oropharyngeal leak pressure were determined at an intracuff pressure of 60 cm H2O. Ease of ventilation was determined by controlling ventilation at 6 mL/kg tidal volume. Any complications were noted and recorded. Device placement was successful in all patients on the first or second attempt (92.4% or 7.6%, respectively) with an insertion time (removal of face mask until first tidal volume) of 44.9 +/- 37.91 s. Adequate ventilation was achieved in all patients and the vocal cords could be visualized by fiberoptic endoscopy in 91.5% of patients. Oropharyngeal leak pressures were 24.1 +/- 5.44 cm H2O. Blood was detected on the device in 8.5% of patients. Complications and patient complaints were minor and quickly resolved. The Ambu laryngeal mask is easy and quick to insert and provides a safe and efficient seal during positive pressure ventilation in nonparalyzed patients scheduled for elective surgery.
Background and objectives: The laryngeal mask is the method of choice for airway management in children during minor surgical procedures. There is a paucity of data regarding optimal management of mechanical ventilation in these patients. The SupremeTM airway laryngeal mask offers the option to insert a gastric tube to empty the stomach contents of air and/or gastric juice. The aim of this investigation was to evaluate the impact of positive end-expiratory positive pressure (PEEP) levels on ventilation parameters and gastric air insufflation during general anesthesia in children using pressure-controlled ventilation with laryngeal mask. Materials and Methods: An observational trial was carried out in 67 children aged between 1 and 11 years. PEEP levels of 0, 3 and 5 mbar were tested for 5 min in each patient during surgery and compared with ventilation parameters (dynamic compliance (ml/cmH2O), etCO2 (mmHg), peak pressure (mbar), tidal volume (ml), respiratory rate (per minute), FiO2 and gastric air (ml)) were measured at each PEEP. Air was aspirated from the stomach at the start of the sequence of measurements and at the end. Results: Significant differences were observed for the ventilation parameters: dynamic compliance (PEEP 5 vs PEEP 3: p < 0.0001, PEEP 5 vs PEEP 0: p < 0.0001, PEEP 3 vs PEEP 0: p < 0.0001), peak pressure (PEEP 5 vs PEEP 3: p < 0.0001, PEEP 5 vs PEEP 0: p < 0.0001, PEEP 3 vs PEEP 0: p < 0.0001) and tidal volume (PEEP 5 vs PEEP 3: p = 0.0048, PEEP 5 vs PEEP 0: p < 0.0001, PEEP 3 vs PEEP 0: p < 0.0001). All parameters increased significantly with higher PEEP, with the exception of etCO2 (significant decrease) and respiratory rate (no significant difference). We also showed different values for air quantity in the comparisons between the different PEEP levels (PEEP 5: 2.8 ± 3.9 mL, PEEP 3: 1.8 ± 3.0 mL; PEEP 0: 1.6 ± 2.3 mL) with significant differences between PEEP 5 and PEEP 3 (p = 0.0269) and PEEP 5 and PEEP 0 (p =0.0209). Conclusions: Our data suggest that ventilation with a PEEP of 5 mbar might be more lung protective in children using the Supreme™ airway laryngeal mask, although gastric air insufflation increased with higher PEEP. We recommend the use of a laryngeal mask with the option of inserting a gastric tube to evacuate potential gastric air.
LMA-Classic and Ambu laryngeal masks are suitable for rapid and reliable airway management in patients with cervical immobilization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.