The design and execution of consolidation treatment of settled foundations by means of injection of polyurethane expanding resins require a proper investigation of the state of the foundation soil, in order to better identify anomalies responsible for the instability. To monitor the injection process, a procedure has been developed, which involves, in combination with traditional geotechnical tests, the application of a noninvasive, geophysical technique based on the electrical resistivity, which is strongly sensitive to presence of water or voids. Three-dimensional electrical resistivity tomography is a useful tool to produce effective 3D images of the foundation soils before, during, and after the injections. The achieved information allows designing the consolidation scheme and monitoring its effects on the treated volumes in real time. To better understand the complex processes induced by the treatment and to learn how variations of resistivity accompany increase of stiffness, an experiment was carried out in a full-scale test site. Injections of polyurethane expanding resin were performed as in real worksite conditions. Results confirm that the experimented approach by means of 3D resistivity imaging allows a reliable procedure of consolidation, and geotechnical tests demonstrate the increase of mechanical stiffness.
The characterization of soil settlements below foundations of buildings using surface waves methods represent an extreme challenging problem because of the presence of localized shear waves variation and shallow heterogeneity. To tackle the near-foundation shear waves distribution reconstruction challenge a method for the elaboration of surface waves recordings unbound from both rigid field geometry and from the classic layered subsurface assumption would be highly desirable. We introduce a novel elaboration strategy of surface waves data, based on the Direct Interpretation of Phase Lags (DIPL-3D)among pairs of seismic signals which aims to retrieve the three dimensional shear waves velocity subsurface distribution without using inversion. As an example application, the method is used for the evaluation of near foundation soil stiffening after an expanding resins injection interventio
Settlements of ground subjected to foundation load are often due to both natural and/or anthropogenic causes, such as differential consolidation, seepage, periods of drought alternating with heavy rainfalls, growth of tree roots, sewer leaks, vibrations induced by vehicle traffic, excavations, or construction defects. Techniques of soil consolidation and stabilization by means of injection of polyurethane expanding resins have been efficiently used to mitigate or even solve this issue. The efficiency of the resin injection treatment has been well documented also thanks to the develop of a procedure of planning and monitoring which combines traditional geotechnical tests with the application of electrical resistivity tomography, which is strongly sensitive to the presence of water or voids. The combination of these survey methodologies allows to recognize the effect of injection in terms of soil compaction and water migration, a key factor for understanding the phenomenon and planning of resolutive interventions. The present study follows a previous work aimed at evaluating the increase in the geotechnical performance of cohesive soils treated by injection of expanding resins (same soil, resin, at the same site) and integrates it by focusing on the quantification of the effects of consolidation treatments, by means of expanding resins injection, on hydrologic properties of cohesive soils, focusing on saturated hydraulic conductivity measurements. Laboratory permeability test, performed in triaxial cell at different stress conditions and hydraulic gradients, were performed on undisturbed samples collected on “natural (non-treated)” and “treated soils”, before and after the injection of resin (MAXIMA ® by GEOSEC ® ) in a full-scale test site characterized by the presence of continuous and homogeneous cohesive soils, (clay and silts). The investigated soil is classified as CH or CL soil, very firm and apparently overconsolidated. The study shows how the treatment is able to modify the characteristics of hydraulic conductivity of the soil. The injected resins partly follow pre-existing weaknesses and partly impregnate homogeneous and continuous masses of soil in a capillary way, giving it, in addition to the already documented greater mechanical strength, a lower hydraulic conductivity. The electrical resistivity investigations allow to appreciate the volumes affected by the treatment to which the variations of the measured properties can be attributed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.