In order to define the changes in intracranial pressure which occur during tracheal intubation in young infants, a Ladd transducer was used to monitor anterior fontanelle pressure (AFP) non-invasively in awake (group 1, n = 14) and anaesthetized (group 2, n = 10) infants during intubation of the trachea. Heart rate and systolic arterial pressure were also recorded. In quiet, undisturbed infants, AFP (mean +/- SEM) was similar in groups 1 (9.6 +/- 0.5 mm Hg) and 2 (8.7 +/- 0.8 mm Hg); with crying, AFP increased significantly in both groups. During laryngoscopy in group 1, AFP increased to 33.5 +/- 3.6 mm Hg, which was significantly greater than in the quiet infant, but did not differ significantly from measurements in the crying infant. In group 2, AFP increased significantly to 15.8 +/- 18 mm Hg during laryngoscopy. This increase was significantly less than the group 1 response. Neither heart rate nor systolic arterial pressure changed significantly in either group during laryngoscopy--when compared with measurements in the quiet state. It was concluded that AFP increases significantly during intubation and during crying in the infant. The response to intubation is only partially attenuated by the prior administration of general anaesthesia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.