Inaccurate electrode placement and differences in inter-individual human anatomies can lead to misinterpretation of ECG examination. The aim of the study was to investigate the effect of precordial electrodes displacement on morphology of the ECG signal in a group of 60 patients with diagnosed cardiac disease. Shapes of ECG signals recorded from precordial leads were compared with signals interpolated at the points located at a distance up to 5 cm from lead location. Shape differences of the QRS and ST-T-U complexes were quantified using the distribution function method, correlation coefficient, root-mean-square error (RMSE), and normalized RMSE. The relative variability (RV) index was calculated to quantify inter-individual variability. ECG morphology changes were prominent in all shape parameters beyond 2 cm distance to precordial leads. Lead V2 was the most sensitive to displacement errors, followed by leads V3, V1, and V4, for which the direction of electrodes displacement plays a key role. No visible changes in ECG morphology were observed in leads V5 and V6, only scaling effect of signal amplitude. The RV ranged from 0.639 to 0.989. Distortions in ECG tracings increase with the distance from precordial lead, which are specific to chosen electrode, direction of displacement, and for ECG segment selected for calculations.
SummaryBackgroundThe effective screening of myocardial infarction (MI) patients threatened by ventricular tachycardia (VT) is an important issue in clinical practice, especially in the process of implantable cardioverter-defibrillator (ICD) therapy recommendation. This study proposes new parameters describing depolarization and repolarization inhomogeneity in high resolution body surface potential maps (HR BSPM) to identify MI patients threatened by VT.Material/MethodsHigh resolution ECGs were recorded from 64 surface leads. Time-averaged HR BSPMs were used. Several parameters for arrhythmia risk assessment were calculated in 2 groups of MI patients: those with and without documented VT. Additionally, a control group of healthy subjects was studied. To assess the risk of VT, the following parameters were proposed: correlation coefficient between STT and QRST integral maps (STT_QRST_CORR), departure index of absolute value of STT integral map (STT_DI), and departure index of absolute value of T-wave shape index (TSI_DI). These new parameters were compared to known parameters: QRS width, QT interval, QT dispersion, Tpeak-Tend interval, total cosines between QRS complex and T wave, and non-dipolar content of QRST integral maps.ResultsSTT_DI, TSI_DI, STT_QRST_CORR, QRS width, and QT interval parameters were statistically significant (p≤0.05) in arrhythmia risk assessment. The highest sensitivity was found for the STT_DI parameter (0.77) and the highest specificity for TSI_DI (0.79).ConclusionsArrhythmia risk is demonstrated by both abnormal spatial distribution of the repolarization phase and changed relationship between depolarization and repolarization phases, as well as their prolongation. The proposed new parameters might be applied for risk stratification of cardiac arrhythmia.
The aim of the study was a selection of best ECG leads to get the significant T-wave alternans signal (TWA)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.